October
- Last UpdatedOct 29, 2026
- 8 minute read
These release notes describe the enhancements, resolved issues and general information for Asset Information Management (AIM) 6.1. It is a Full Main Release.
This Release Contains
A full release of AVEVA Asset Information Management 6.1, which upgrades the full release of AVEVA Asset Information Management 6.0.
Prerequisite for this Release - Operating System
|
Prerequisites |
Version Details |
|---|---|
|
Server Environment |
Please refer to the AVEVA AIM documentation available in the Hardware and Software Requirements topic. |
|
Client Environment |
|
|
Mobile Environment |
Note: The recommended/supported hardware and software configurations are constantly subject to review, so please consult the AVEVA support web pages for the latest recommendations.
Prerequisite for this release - products
AVEVA Licensing System 5.0 or latest and an appropriate licence file. For further details, see https://softwaresupport.aveva.com.
Works (is compatible with)
Please see the Technology Matrix for compatible technologies and products at AVEVA Asset Information Management 6.1 x64 - Technology Matrix.
|
Name of the Product |
Version No. |
|---|---|
|
Accusoft PrizmDoc (included with AIM) |
14.10 |
Auth0 Support
Auth0 is only supported as an authentication provider with CONNECT.
AIM supports the OpenID Connect protocol. However, we test with Auth0 supported by CONNECT, but we do not test it with every authentication provider available on market
To Install this product release
Please read the installation guide, which is available at https://docs.aveva.com/bundle/asset-information-management/page/1126128.html.
Notes:
-
To enhance the security there is a provision to create encryption keys before deployment and the same keys can be used during the installation.
-
This increases security and safeguards critical information such as databases, services and application pool passwords.
-
The key created must be securely stored at a location accessible across multiple machines while installing the applications.
-
In addition, ACLs (Access Control Lists) can be applied to the configuration file to define fine-grained permissions for different users.
-
-
The Import, Job, FileStore and EIA services will run with the virtual service account by default instead of Local System. These services can run with the minimum privileges required.
-
When installing Microsoft SQL Server, ensure that the Full-Text Search feature is selected in the Feature Selection window.
-
While upgrading from a version 5 installation, any new files you have added are deleted, and all files delivered with the application, are overwritten. This includes:
-
web.config settings, such as additional Portal IDs.
-
AVEVA.NET.Import.Server.exe.Config settings, such as database related details.
-
-
The 3D Viewer has been enhanced to support saving and restoring multiple viewpoints per model, as well as importing viewpoints from Navisworks (.NWD) model files through 3D Gateway. Additional improvements include enhanced default MarkUp behavior, optional model position shifting, and configurable default camera posture settings.
-
All 3D models require reprocessing through Import Controller and any markups created on 3D with earlier versions of AIM will be deleted and needs to be recreated.
-
The name of the authentication provider for AIM-hybrid has been changed from AIMHybrid3DVS to AIMHybrid. This change requires updating the authenticationProvider parameter in the web.config file.
Statement of Withdrawal
Technologies that have been withdrawn at this release.
-
Windows Server 2019
-
SQL Server 2019
Product Quality Statement
The development, maintenance and testing of AVEVA Solutions’ software products is carried out in accordance with the AVEVA Quality Management System lifecycle processes and this document includes a summary of the testing carried out on this release and a list of significant defects known to exist at the time of release.
Development Testing
Developers have performed unit testing of each enhancement and/or fix in the development environment to verify that any new functionalities have been correctly implemented and identified defects have been corrected.
Regression tests have been run in the development environment to verify that enhancements and/or fixes have not adversely affected the integrity of the product.
System Testing
Independent system testing has been carried out on the product, as released, to verify that it installs correctly in all supported configurations and that product functionality operates as intended, subject to any known exceptions listed below.
Acceptance Testing
This document has been prepared before Acceptance Testing. This product release will be subjected to an acceptance test by AVEVA’s System Test team.
Any exceptions found during Acceptance Testing or after release will be reported in the Product Release Latest Update Note on AVEVA's support web site. https://softwaresupport.aveva.com/.
Content
List of enhancements
This release includes the following functional enhancements:
|
Internal Number |
Customer Number |
Description |
|---|---|---|
|
3745324 |
Viewpoints can now be saved and restored in the 3D viewer, including for model compositions and multi-model compositions (MMC). A viewpoint can be set as a personal or shared default. |
|
|
4417891 |
Viewpoints extracted by Gateway for 3D Data from Navisworks (NWD) models can now be imported through the Import Controller with the converted 3D model and viewed in AIM. |
|
|
4351459 |
You can now navigate with the keyboard in Walk mode in the 3D viewer. |
|
|
4350390 |
960616531 |
When a 3D model is opened from a tag Content Card or another contextual entry point, it is now displayed without the default markup. |
|
4350389 |
Performance improvements have been made to Visual Reporting when applying visuals in the UI, especially for large models. |
|
|
3910520 |
A Reset option has been added to the Visual Reporting pane for the 2D and 3D viewers. Select Reset and then Run to clear all changes made to the visual report. |
|
|
4571278 |
960661082 |
A new site setting controls whether the Tag Summary page refreshes when you return to a previously opened tab. With refresh turned off, the page keeps its state. |
|
4572313 |
960581857 |
The Delete option is now available in the Actions menu for sets in the Summary View, simplifying set management. |
|
4962221 |
962866581 |
AIM has been validated with SQL Server TLS encryption (encryption in transit) and Transparent Data Encryption (TDE, encryption at rest) enabled. |
List of Fault Corrections
This release addresses defects arising from the following support incidents:
|
Internal Number |
Customer Number |
Description |
|---|---|---|
|
4574583 |
962716871 |
With WS-Federation authentication, opening AIM in a new browser after closing all tabs shows the logout screen instead of logging the user in. |
|
5100826 |
962933402 |
Opening a SharePoint Online document shows a Windows login prompt, and the user cannot log in with valid credentials. |
|
4998289 |
962877455 |
Clicking objects rapidly in a 3D model selects multiple objects even though the Ctrl key is not pressed. |
|
4996984 |
962867103 |
For users whose role has Context Access Control configured, documents linked through the is fulfilled by association fail to open with an HTTP 404 error. |
|
4831493 |
962801733 |
Attribute counts on the Tag Summary page do not match the number of attributes displayed. |
|
4782016 |
962786399 |
With Microsoft Entra ID authentication, users in more than 200 groups exceed the token group limit. AIM now gets group memberships from Microsoft Graph. |
|
4772676 |
962786399 |
With Microsoft Entra ID authentication, clicking a tag in an SVG drawing does not open the tag Content Card. |
|
4818367 |
962834626 |
When several SVG files are printed together from the Basket or search results, elements are missing from the second page onwards. |
|
4814880 |
962809984 |
Some PDF documents are pixelated when printed from the Basket or search results. |
|
4830843 |
962829901 |
With PDF in-memory tabs enabled, expanding tabs in one document collapses the tabs in another open document. |
|
4669494 |
962753603 |
Logging in is slow when Active Directory groups are used for authentication. |
|
4726532 |
962771528 |
In a Query Form, switching to Table View without entering criteria shows results automatically, and the page selector shows an invalid state. |
|
4225805 |
960666064 |
The SVG viewer does not work correctly on iPadOS. |
|
4483801 |
962668884 |
In Query Form results for Document Content with a related Pump, Name values are misaligned with their IDs. |
|
3807528 |
960523454 |
An attribute removed from the XML file is not deleted when the file is re-imported through the Import Service. |
|
4500166 |
962640570 |
The Content Card of an unknown object opens even when Show items of unknown type is disabled for the user role. |
|
4400323 |
962621096 |
On iPad Air 11-inch (M3), the 3D viewer is cropped and its toolbar is hard to reach. |
|
4416986 |
960532123 |
Opening a PCM model from the Tag Summary page sometimes opens the PCM project without zooming to the tag. |
|
4514959 |
962669648 |
The 3D viewer toolbar disappears when the browser height is reduced. |
|
4446987 |
962640717 |
A DataGroup whose projection characteristics are defined on a single line repeats the object name in the Dashboard. |
|
4377090 |
960661082 |
Switching between open tabs does not keep the last action performed on a page. |
|
4275030 |
960662560 |
Some instrument tags are not hotspotted in P&ID drawings. |
|
3913671 |
960541173 |
When two attribute groups contain an attribute with the same name, the attribute is shown under the wrong attribute group. |
|
4248308 |
960625353 |
In the document viewer, a tag whose ID contains another tag ID (for example, FPP-106 and P-106) is not hotspotted. |
|
4295553 |
960653951 |
Some documents opened through an info locator fail to load in the PrizmDoc viewer. |
|
4109647 |
960655070 |
Status badges in the tag Content Card overlap. |
|
3886147 |
960552068 |
Search results for a custom role show the class ID (Type ID) instead of the class name (Type). |
|
4230139 |
960654505 |
The Search button is disabled when Tags is selected in the search type list. |
|
3999161 |
960441284 |
Searches run as the default user return objects of unknown type. |
|
4249148 |
960638113 |
With Microsoft Office installed, CSV files downloaded with Download Original File are saved as .csv,.xls. |
|
4079457 |
The Isolate results option is displayed in the Visual Reporting dialog for SVG drawings. |
|
|
4056063 |
When exporting markup, the file download dialog does not close automatically after the download completes. |
|
|
4930077 |
The printer-friendly view of Query Form results in Table View does not load. |
|
|
3875842 |
With several 3D models open in tabs, actions on tags show an unnecessary The item(s) is not in the model so can't be selected message. |
|
|
4093030 |
In the 2D viewer, Clear Selected Highlights does not fully reset the selection, so elements that are not selected can change colour. |
|
|
4378843 |
Opening or refreshing the URL of an object whose ID contains / shows an Item not found error. |
|
|
4229677 |
The Visual Reporting pane in the SVG viewer breaks when switching to another tab and back. |
Known Issues
AVEVA intends to fix the defects listed below in a fix release or service pack as soon as reasonably possible.
|
Incident number |
Defect number |
Description |
Recommended Workaround |
|---|---|---|---|
|
2044058 |
When a file fails to load in the PrizmDoc viewer, then it should automatically open in a new browser, but this is not happening for Documents with revisions set. |
When the file fails to load in the PrizmDoc viewer, explicitly choose Actions >> Open in Browser Tab. |
|
|
2909023 |
After creating a role, via XML, with a name of Admin, then the Admin user was unable to log into the Admin Tool. |
Avoid creating a role with the name of Admin. |
|
|
3440341 |
The first attempt of deployment on a new Virtual Machine may not be successful. If the user checks the Reports component, then a configuration error of Unable to find Microsoft SQL Server Data Transformation Services on this machine may be given. |
Re-try the deployment. The second attempt should be successful. |
For the latest list of exceptions and other updates, please see the Product Release Latest Update Note on AVEVA's support web site https://softwaresupport.aveva.com.