October
- Last UpdatedOct 22, 2025
- 3 minute read
This document provides the latest Release Notes 25.10 for AVEVA Asset Information Management - Advanced.
Content
This release contains the following significant enhancements and defect fixes:
Core Functionality
|
Reference |
Type |
Description |
|---|---|---|
|
4268042 |
Process |
Updated the release to the latest Microsoft patches. |
|
3910520 |
Enhancement |
Reset button in Visual Reporting for 2D/3D Reset button is added in the Visual Reporting pane for both 2D and 3D viewers. To reset all the changes made to the visual report, select Reset option followed by Run. This functionality is not implemented for Arf 3D viewer. For further information, see: https://docs.aveva.com/bundle/asset-information-management/page/994651.html https://docs.aveva.com/bundle/asset-information-management/page/1486237.html |
|
4029692 |
Enhancement |
Enhance behavior of object selection in 3DVis When a user selects any other tag from the content tab after selecting a tag, all the previously selected tags will now be cleared, and we can only see the newly selected tag. |
|
4093030 |
Defect |
Fixed issue where the Clear Selected Highlights button did not fully reset the selection state. |
|
3999161 960441284 |
Defect |
Search and related-item results now exclude associated items whose ClassId is UNKNOWN, preventing unclassified objects from appearing in Search, Advanced Search and Query Form results. No action is required — the change takes effect with the update. |
|
4092323 4059326 |
Defect |
Accusoft viewer now correctly handles document IDs containing square brackets enabling hotspotting and hyperlink creation for both bracketed and non-bracketed document IDs. |
|
3730941 3597036 |
Defect |
Display the correct metadata in the content card when a tag is highlighted but the tag shares the same name as a separate document. |
Document Connector
|
Reference |
Type |
Description |
|---|---|---|
|
4091748 |
Process |
Updated the release to the latest Microsoft patches. |
|
3899699 3908311 |
Defect |
Extend supported file types to include xlsm extension. |
|
4288243 4107227 |
Defect |
Aconex - Missing document filename from metadata for documents without a physical file associated. |
Data Pipeline
|
Reference |
Type |
Description |
|---|---|---|
|
4280779 |
Process |
Updated the release to the latest Microsoft patches. |
|
4082339 4080356 |
Defect |
Fixed an issue where some files with similar names (different suffix) remained stuck in the Processing state during file ingestion. All files now correctly move to Completed or Failed status. |
Data Pipeline – Load Reporting
|
Reference |
Type |
Description |
|---|---|---|
|
4062595 |
Process |
Updated the release to the latest Microsoft patches. |
|
3855623 |
Enhancement |
Remediation messages now supported for files processed by the 2D Gateway, in a similar manner as other file types. Note: The remediation text is sourced from the error file generated by the gateway when a file fails processing. |
|
4082774 3915683 |
Defect |
Ensures that unexpected 3D RAW file conversion failures are correctly reported in load reporting. When a conversion fails, the file status is now marked as Failed instead of remaining In Progress. |
Known Issues
|
Reference |
Description |
|---|---|
|
1899246 960156293 |
When viewing or printing Excel spreadsheets, excess white space can be present down the right-hand side and along the bottom. If this is an issue, we recommend opening the file in a new browser tab, using the following option:
In the new browser tab, the file can be viewed, then printed using the built-in browser print functionality. |
|
3875842 |
When viewing 3D models (3DVis), performing actions on selected tags, such as isolate, may briefly show the message The item(s) is not in the model, so can’t be selected.. The action still succeeds. This may happen if another model is open that does not have the tag(s) in its model. |
|
3991042 4012886 |
The lines drawn by the output SVG file from a DEXPI file may appear faint in the viewer. |
