The following procedure describes how to configure AVEVA™ Electrical to point to AVEVA™ Integration Service (Service) for obtaining data from AVEVA™ Diagrams. This section assumes that you have already installed AVEVA™ Electrical, AVEVA™ Diagrams and AVEVA™ Integration Service.
For information on how to configure AVEVA™ Diagrams as the data source for the Service using Integration Settings Editor, see AVEVA Diagrams.
Note: This section describes the procedure for AVEVA™ Electrical Engineer 12.1 SP5. The steps and the screen shots may vary slightly for the other versions of AVEVA™ Electrical Engineer.
To configure AVEVA™ Electrical as client:
-
Open Electrical Engineer.
-
From the Select an AVEVA Electrical Project dialog box, click the required project, and then click Select.
-
On the Project tab, click Setup, select AVEVA Integration Service, and then Import Configuration.

-
On the Service Import Configuration Settings dialog box, select Service for the list in the Actions area.

-
On the Configure Integration Service Location dialog box, for the Service Installed On box, enter the computer name on which AVEVA™ Integration Service is installed, and then click Save.
-
Click Test Service to verify if the connection to the service has been established.
-
Click Exit after the Service Ok message is displayed.
-
On the Service Import Configuration Settings dialog box, for the Select Source list, select AVEVA Diagrams and then click Login.

-
On the Select an AVEVA Diagrams Project dialog box, select the project, provide the credentials, and then click Connect.
-
On the Step 1 of 5: Choose mode of operation page, select Create new configuration, and then click Next.
-
On the Step 2 of 5: Source Element Type page, type a configuration name, and then select the values for the Group, Object Type Mapping, Name Attribute and Unique Attribute lists. The values represent the element types for AVEVA™ Diagrams. Click Next.
-
On the Step 3 of 5: Destination Element Type page, select the object type for AVEVA™ Electrical in the Object Type list, select the Allow Insertion check box, and then click Next.
-
On the Step 4 of 5: Define Source Filter(s) page, click Add Filter to add a condition to filter the data received from AVEVA™ Diagrams. Click Next.
-
On the Step 5 of 5: Define Attribute Mapping(s) page, click Add Mapping to add a mapping to the data.
Note: You can select the Select All Mappings check box based on your need.
-
Click Finish. A message is displayed that the configuration is saved successfully.
-
Click OK.
-
On the Manage tab of AVEVA™ Electrical Engineer, select AVEVA Diagrams for the Products list, and the click Connect.

-
On the Select An AVEVA Diagrams Project dialog box, select the project, enter the password and then click Connect.
-
Select the group name from the Groups list, and then click Import Data. The AVEVA™ Diagrams data can now be viewed in AVEVA™ Electrical.