2023 R2 SP1 P01
- Last UpdatedMar 24, 2025
- 2 minute read
Patch Installation
Communication Drivers Pack 2023 R2 SP1 Patch 01 is a component of the System Platform 2023 R2 SP1 Patch 01 release. CDP 2023 R2 SP1 P01 can be installed only on nodes that have CDP 2023 R2 SP1.
For more information on installing the patch, refer to the System Platform Patch Install readme.
Note: To install additional Communication Drivers on a machine after installing the System Platform patch, select the Communication Drivers Pack program in the control panel and modify the CDP installation. You cannot add additional CDP components after installing the patch by launching the System Platform 2023 R2 SP1 Setup.exe.
Important: The Communication Drivers Pack online help files and AVEVA Help Viewer will not be included or supported in future releases. All product documentation will continue to be available in PDF format on the installation media and on the web at docs.aveva.com.
Resolved Issues
Communication Drivers Core
|
Defect ID |
Case Number |
Description |
|
3503632 |
960536398 |
[DASEngine][DASTKRuntime] When an unknown data type appeared in a row, its data type was locked as a string. When the Communication Driver received the correct data type, it could not be changed. |
|
3622861 |
960495004 |
[PCS] In Communications Driver Pack 2023 R2 SP1, late values were incorrect or duplicated when using the PCS connection. |
Gateway
|
Defect ID |
Case Number |
Description |
|
3490616 / 3630050 |
960423556 / 960497069 |
[OPC UA] Watchdog tags were rejecting pokes to read-only tags. |
|
3580220 |
960476860 |
[OPC UA][Enhancement] Improved Gateway OPC UA client failover performance by adding an option to trigger bad quality during watchdog timeout. |
|
3489426 |
960453501 |
[OPC UA] OCMC would crash with Exception code: 0xc0000005 when executing a TestConnection within the OPC UA Server configuration editor. This was due to an incorrectly formed browse reference received from the OPC UA server. |
|
3676422 |
960328609 |
During a network failure, Gateway topics would disconnect and not return online even after the network connection is reestablished. |
MQTT
|
Defect ID |
Case Number |
Description |
|
3569358 / 3666001 |
960455477 / 960513421 |
OCMC would crash while configuring MQTT, specifically while browsing for CA files. |
OMRONFINS
|
Defect ID |
Case Number |
Description |
|
3625466 |
960493961 |
[DASWrapper] The OMRONFINS driver would stop communicating due to a logic issue when handling write for array tags in DASWrapper. |
WEBSVC
|
Defect ID |
Case Number |
Description |
|
3454770 / 3611264 |
960443892 / 960482344 |
Access tokens would not get generated when using the OAuth 2.0 authentication type. |
|
3647923 |
960502212 |
Requests with invalid tokens were getting through without errors or warning messages. |
Known Issues
There are no known issues in this release of the Communication Drivers Pack.
Workaround: Right-click the Configuration node and select the Use Another Configuration Set option to load the desired configuration set.