Attribute

Item Reference

Access

Datatype

sysDescription

.1.3.6.1.2.1.1.1.0

Read-only

OCTETSTRING

sysUptime

.1.3.6.1.2.1.1.3.0

Read-only

TIMETICKS

sysObjectID

.1.3.6.1.2.1.1.2.0

Read-only

OID

sysContact

.1.3.6.1.2.1.1.4.0

Read/Write

OCTETSTRING

sysName

.1.3.6.1.2.1.1.5.0

Read/Write

OCTETSTRING

sysLocation

.1.3.6.1.2.1.1.6.0

Read/Write

OCTETSTRING

sysServices

.1.3.6.1.2.1.1.7.0

Read-only

INTEGER

snmpInPkts

.1.3.6.1.2.1.11.1.0

Read-only

COUNTER32

snmpOutPkts

.1.3.6.1.2.1.11.2.0

Read-only

COUNTER32

snmpInBadVersions

.1.3.6.1.2.1.11.3.0

Read-only

COUNTER32

snmpInBadCommunityNames

.1.3.6.1.2.1.11.4.0

Read-only

COUNTER32

snmpInBadCommunityUses

.1.3.6.1.2.1.11.5.0

Read-only

COUNTER32

snmpInASNParseErrs

.1.3.6.1.2.1.11.6.0

Read-only

COUNTER32

snmpInTooBigs

.1.3.6.1.2.1.11.8.0

Read-only

COUNTER32

snmpInNoSuchNames

.1.3.6.1.2.1.11.9.0

Read-only

COUNTER32

snmpInBadValues

.1.3.6.1.2.1.11.10.0

Read-only

COUNTER32

snmpInReadOnlys

.1.3.6.1.2.1.11.11.0

Read-only

COUNTER32

snmpInGenErrs

.1.3.6.1.2.1.11.12.0

Read-only

COUNTER32

snmpInTotalReqVars

.1.3.6.1.2.1.11.13.0

Read-only

COUNTER32

snmpInTotalSetVars

.1.3.6.1.2.1.11.14.0

Read-only

COUNTER32

snmpInGetRequests

.1.3.6.1.2.1.11.15.0

Read-only

COUNTER32

snmpInGetNexts

.1.3.6.1.2.1.11.16.0

Read-only

COUNTER32

snmpInSetRequests

.1.3.6.1.2.1.11.17.0

Read-only

COUNTER32

snmpInGetResponses

.1.3.6.1.2.1.11.18.0

Read-only

COUNTER32

snmpInTraps

.1.3.6.1.2.1.11.19.0

Read-only

COUNTER32

snmpOutTooBigs

.1.3.6.1.2.1.11.20.0

Read-only

COUNTER32

snmpOutNoSuchNames

.1.3.6.1.2.1.11.21.0

Read-only

COUNTER32

snmpOutBadValues

.1.3.6.1.2.1.11.22.0

Read-only

COUNTER32

snmpOutGenErrs

.1.3.6.1.2.1.11.24.0

Read-only

COUNTER32

snmpOutGetRequests

.1.3.6.1.2.1.11.25.0

Read-only

COUNTER32

snmpOutGetNexts

.1.3.6.1.2.1.11.26.0

Read-only

COUNTER32

snmpOutSetRequests

.1.3.6.1.2.1.11.27.0

Read-only

COUNTER32

snmpOutGetResponses

.1.3.6.1.2.1.11.28.0

Read-only

COUNTER32

snmpOutTraps

.1.3.6.1.2.1.11.29.0

Read-only

COUNTER32

snmpEnableAuthenTraps

.1.3.6.1.2.1.11.30.0

Read/Write

INTEGER

hostSysUptime

.1.3.6.1.2.1.25.1.1.0

Read-only

TIMETICKS

SysDate

.1.3.6.1.2.1.25.1.2.0

Read/Write

DATEANDTIME

sysFreeSpace
(on drives 1,2,3…)

.1.3.6.1.2.1.25.2.3.1.6.(1,2,3 …)

Read-only

INTEGER (kb)

TitleResults for “How to create a CRG?”Also Available in