AVEVA™ Manufacturing Execution System

Use Spec Configuration to Collect Automatic Data

  • Last UpdatedMar 19, 2016
  • 3 minute read

When a characteristic is configured to Use Configuration To Collect Automatic Data, the timer resets and starts each time a new ready sample is received from the MES database. The start time for the delay timer is the time it receives a new sample in the SRO.

When the time evaluates to True, the SRO collects the result data and the MES result attributes data that are currently available in the SRO, and logs them in the MES database.

The table below indicates how result data from the SRO is captured and logged in the MES database when the SRO is configured to collect a maximum of 4 readings at a time. The characteristic ‘Width’ is linked to different specifications with different time intervals in the MES database.

Specification Name

Characteristic

Automated Collection

Time Interval

Time Interval unit

Max Sample Size

SpecP

Width

No

SpecQ

Width

Yes

30

0 (Seconds)

10

SpecR

Width

Yes

1

1 (Minutes)

16

A value for ValueNo. indicates the value number recorded in the MES database and ValueNumber<N> indicates the SRO attribute from where the value is read.

Scan
Time

Characteris-tic

Sample ID

Spec

Timer Enabled

Time Elapsed (in sec)

Log Data

Comments

04:00:00

Width

200

SpecP

No

No

Timer is not enabled, because SpecP is not configured to collect automatic data.

04:15:40

Width

210

SpecQ

Yes

0

Yes

Timer is enabled, but a new sample ID, having a spec different from the current spec, is received, and SpecQ is configured to collect automatic data. Log Result and Result Attributes Data for sample ID: 210.

ValueNo: 1 (ValueNumber01)

ValueNo: 2 (ValueNumber02)

ValueNo: 3 (ValueNumber03)

ValueNo: 4 (ValueNumber04)

04:16:05

Width

210

SpecQ

Yes

25

No

Timer does not elapse.

04:16:10

Width

210

SpecQ

Yes

30

Yes

Log Result and Result Attributes Data for sample ID: 210.

ValueNo: 5 (ValueNumber01)

ValueNo: 6 (ValueNumber02)

ValueNo: 7 (ValueNumber03)

ValueNo: 8 (ValueNumber04)

04:16:20

Width

210

SpecQ

Yes

10

No

Timer does not elapse.

04:16:40

Width

210

SpecQ

Yes

30

Yes

Log Result and Result Attributes Data for sample ID: 210.

ValueNo: 9 (ValueNumber01)

ValueNo: 10 (ValueNumber02)

04:16:41

Width

210

SpecQ

Yes

1

No

Timer stops.

04:17:10

Width

210

SpecQ

Yes

30

No

Timer does not running because the maximum number of individual readings for the sample is already taken. No reading is logged.

04:17:40

Width

210

SpecQ

Yes

30

No

Timer does not running because the maximum number of individual readings for the sample is already taken. No reading is logged.

04:17:50

Width

220

SpecR

Yes

0

Yes

Timer is enabled, but a new sample ID, having a spec different from the current spec, is received, and SpecR is configured to collect automatic data. Log Result and Result Attributes Data for sample ID: 220.

ValueNo: 1 (ValueNumber01)

ValueNo: 2 (ValueNumber02)

ValueNo: 3 (ValueNumber03)

ValueNo: 4 (ValueNumber04)

04:18:45

Width

220

SpecR

Yes

55

No

Timer does not elapse.

04:18:50

Width

220

SpecR

Yes

60

Yes

Log Result and Result Attributes Data for sample ID: 220.

ValueNo: 5 (ValueNumber01)

ValueNo: 6 (ValueNumber02)

ValueNo: 7 (ValueNumber03)

ValueNo: 8 (ValueNumber04)

04:19:50

Width

220

SpecR

Yes

60

Yes

Log Result and Result Attributes Data for sample ID: 220.

ValueNo: 9 (ValueNumber01)

ValueNo: 10 (ValueNumber02)

ValueNo: 11 (ValueNumber03)

ValueNo: 12 (ValueNumber04)

04:20:50

Width

220

SpecR

Yes

60

Yes

Log Result and Result Attributes Data for sample ID: 220.

ValueNo: 13 (ValueNumber01)

ValueNo: 14 (ValueNumber02)

ValueNo: 15 (ValueNumber03)

ValueNo: 16 (ValueNumber04)

04:21:50

Width

220

SpecR

Yes

60

No

Timer stops, because the maximum number of individual readings for the sample is already taken. No reading is logged.

04:22:50

Width

220

SpecR

Yes

60

No

Timer stops, because the maximum number of individual readings for the sample is already taken. No reading is logged.

04:23:00

Width

230

SpecR

Yes

0

Yes

Timer is enabled, and a new sample ID is received. SpecR is configured to collect automatic data. Log Result and Result Attributes Data for sample ID: 230.

ValueNo: 1 (ValueNumber01)

ValueNo: 2 (ValueNumber02)

ValueNo: 3 (ValueNumber03)

ValueNo: 4 (ValueNumber04)

04:24:00

Width

230

SpecR

Yes

60

Yes

Log Result and Result Attributes Data for sample ID: 230.

ValueNo: 5 (ValueNumber01)

ValueNo: 6 (ValueNumber02)

ValueNo: 7 (ValueNumber03)

ValueNo: 8 (ValueNumber04)

04:24:30

Width

240

SpecP

No

No

A new sample ID is received, which is linked to a spec that is not configured to collect automatic data. Hence, the timer is disabled.

04:25:00

Width

240

SpecP

No

No

Timer is not enabled, because SpecP is not configured to collect automatic data.