Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Manufacturing Execution System

Live Migration

  • Last UpdatedMay 17, 2023
  • 1 minute read

Applications

Scenario

RTO (sec)

RPO (sec)

MES Middleware server

Top of the minute

14

0

MES Middleware server

Top of the hour

12*

0

MES Middleware server

Top of the day

4

0

MES Middleware server

During shift change

12

0

Application Object Server hosting the machine shop application

During normal execution

4

0

MES Middleware server

When an archive job is in progress

9

0

MES Middleware server

When a purge job is in progress

11

0

*There was one warning in Operations Control Management Console Log Viewer immediately following the Live Migration at top of the hour:

Had trouble closing connection on Dispose - The socket transfer timed out after 00:00:05. You have exceeded the timeout set on your binding. The time allotted to this operation may have been a portion of a longer timeout.

There were two warnings in the Middleware node Operations Control Management Console Log Viewer immediately following the Live Migration at top of the hour:

SyncCmdSvc.ExecCmd - clientId [MiddlewareVM.DefaultDomain.28] --> Violation of PRIMARY KEY constraint 'PK_tpm_stat'. Cannot insert duplicate key in object 'dbo.tpm_stat'… .