Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Manufacturing Execution System

np Chart

  • Last UpdatedMar 19, 2016
  • 2 minute read

The following table contains the formulas used to calculate LCL and UCL for a chart point.

The example in the table illustrates the control limits calculated for a sample size of 15.

Formula

Example

CL = pBar * n

LCL = CL – (3 * ControlRuleVioNPChartEq1)

UCL = CL + (3 * ControlRuleVioNPChartEq1)

where n is the actual sample size from the sample.

If LCL < 0, then LCL = 0; otherwise LCL

pBar = 0.17647

CL = 0.17647 * 15 = 2.64706

LCL = 2.64706 – (3 * ControlRuleVioNPChartEq2)

= –1.78232

LCL = 0

UCL = 2.64706 + (3 * ControlRuleVioNPChartEq2)

= 7.07644

The following table shows example control limits calculated for each chart point.

Label

Chart Point (Count)

Size

LCL

CL

UCL

Lower σ

Upper σ

1

2

15

0

2.647059

7.076435

0.882353

1.47645867

2

1

9

0

1.588235

5.019215

0.5294117

1.14366

3

3

15

0

2.647059

7.076435

0.882353

1.47645867

4

1

15

0

2.647059

7.076435

0.882353

1.47645867

5

4

15

0

2.647059

7.076435

0.882353

1.47645867

6

6

20

0

3.529412

8.6440153

1.176470

1.70486785

7

1

15

0

2.647059

7.076435

0.882353

1.47645867

8

3

15

0

2.647059

7.076435

0.882353

1.47645867

TitleResults for “How to create a CRG?”Also Available in