BI Gateway Server

AVEVA BI Gateway.EMIRuntime.StorageType

Data store storage type. The default and only option supported by MES is SQL Server.

AVEVA BI Gateway.EMIRuntime.DSServerName

The name of the server on which the BI Gateway database is stored. The default is localhost.

AVEVA BI Gateway.EMIRuntime.DatabaseName

The name of the BI Gateway database. The default is the name of the existing BI Gateway database. Otherwise, the default is BIGateway_DataStore.

AVEVA BI Gateway.EMIRuntime.AuthenticationMode

The default and only option is Windows Integrated Security. The currently logged-in Windows user account will be used to access SQL Server. No user name or password has to be specified in the response file.

AVEVA BI Gateway.EMIRuntime.DataFilePath

The file path at which to store the datalog file. The default path depends on the version of SQL Server. An example is C:\Program Files\Microsoft SQL Server\MSSQL11.MSSQLSERVER\MSSQL\DATA.

AVEVA BI Gateway.EMIRuntime.LogFilePath

The file path at which to store the log file. The default path depends on the version of SQL Server. An example is C:\Program Files\Microsoft SQL Server\MSSQL11.MSSQLSERVER\MSSQL\DATA.

AVEVA BI Gateway.EMIRuntime.UserName

The username of the user account under which the BI Gateway Server service runs.

AVEVA BI Gateway.EMIRuntime.Password

The password of the user account under which the BI Gateway Server service runs.

AVEVA BI Gateway.EMIRuntime.Domain

The domain of the user account under which the BI Gateway Server service runs.

Data Adapter

AVEVA BI Gateway.EMIAdapterCommon.RuntimeServicePort

The number of the service port over which the BI Gateway Server and Data Adapter will communicate. The default is 8732.

AVEVA BI Gateway.EMIAdapterCommon.UserName

The username of the user account under which the BI Gateway Data Adapter service runs.

AVEVA BI Gateway.EMIAdapterCommon.Password

The password of the user account under which the BI Gateway Data Adapter service runs.

AVEVA BI Gateway.EMIAdapterCommon.Domain

The domain of the user account under which the BI Gateway Data Adapter service runs.

BI Gateway Model Builder

AVEVA BI Gateway.EmiModelConfig.ModelApiPortNo

The number of the service port over which the BI Gateway Event API service will communicate. The default is 61076.

AVEVA BI Gateway.EmiModelConfig.ModelBuilderPortNo

The number of the service port over which the BI Gateway Model Builder service will communicate. The default is 61075.

AVEVA BI Gateway.EmiModelConfig.AddIntelligenceModelConfigUsertoGroup

Values are:

  • True: The default. The currently logged-in user will be added to the aaIntelligenceConfigAdmin Windows group, which has Read/Write access to BI Gateway Model Builder. If additional users need to run BI Gateway Model Builder, they can be manually added to this group.

  • False: The currently logged-in user will not be added to the aaIntelligenceConfigAdmin Windows group. If this option is selected, one or more users will have to be manually added to this group so that they can run BI Gateway Model Builder.