IMS 539797 |
Create WO from Process fails if the first operation includes a specification and the next operation has multiple entities. Cannot insert duplicate key in object 'dbo.job_spec'. |
|
IMS 560891 |
Shifts not changing on some entities tracking labor. |
|
IMS 561009 |
Editing a final reason for a utilization event does not change the Category; it is leaving the original one. |
|
IMS 564097 |
Ending multiple jobs at one time takes a long time. |
|
IMS 564325 |
Stateless API StorageExec.ReduceInv() method's Dateout parameter is not saved in the MES database. |
|
IMS 565784 |
MES service is timing out when executing stored procedure sp_U_Sample_UpdateStatus. |
|
IMS 577706 |
Undeploy/deploy of OCO causes rolling counters to improperly increment when using input source. |
|
IMS 620413 |
The latest start time and required finish time for jobs on a multi-operation process are incorrect when percent to start is configured. |
|
IMS 626235 |
Can't end a job with multiple long running jobs in the database. |
|
IMS 644716 |
Entity Allowable Reason Group settings are getting cleared when viewing them and then adding a new allowable reason group to a different entity. |
|
IMS 690874 |
Linking an item to a process times out when thousands of entities are associated to operations in the process |
|
IMS 739856 |
The Stateless API Prod.ItemReasGrpEntLink.GetReasons method is ignoring item_id. |
|
IMS 740518 |
Item and item class specification are not saved when removing another one. |
|
IMS 805244 |
Create Work Order from Process times out. |
|
IMS 826084 |
Control rule check is skipped when multiple entities have same characteristic, there are different request times, and the later request time sample results are recorded before the earlier sample. |
|
IMS 826093 |
Middleware configuration does not accept the user in the username@domain format. |
|
IMS 828969 |
Support single sign-on when MES .NET control is used in AVEVA OMI and the auto login user property is enabled. |
|
IMS 831519 |
HF L00159969 for MES 6.0: On a Terminal Server node, MES middleware periodically denies connections and fails to record or read data. |
|
IMS 834929 |
HF L00159969 for MES 6.2: On a Terminal Server node, MES middleware periodically denies connections and fails to record or read data. |
|
IMS 840286 |
Using Australian regional settings (dd/mm/yyyy), MES Client can create a work order but cannot update a work order. |
|
IMS 860392 |
Related to HF L00153970: With 64-bit applications, the error "Client Proxy configuration settings are missing" is logged. |
|
IMS 861467 |
Stored procedure sp_i_Item_Cons_AddConsPostExec allows for NULL shift start time, which makes queries of the item_cons table to be slow. |
|
IMS 888530 |
IMS 860392 for 6.2: Related to HF L00153970: With 64-bit applications, the error "Client Proxy configuration settings are missing" is logged. |
|
IMS 1052245 |
MES service deadlock occurs when executing stored procedure sp_U_Sample_UpdateStatus while inserting a new result at the same time. |
|
IMS 1055331 |
MES Web API SampleCharLink method does not provide the UOM and number of decimals properties. |
|
IMS 1092380 |
Importing an attribute item with a space character using SCC is creating a record when it shouldn't. |
|
IMS 1148093 |
Continuation of IMS 826084 for Xbar-Sigma chart: Control rule check is skipped when multiple entities have the same characteristic, there are different request times, and the later request time sample results are recorded before the earlier sample. |
|
IMS 1209336 |
HF 826084 and 1148093 for MES 6.2: Control rule check is skipped when multiple entities have same characteristic, there are different request times, and the later request time sample results are recorded before the earlier sample. |
|
IMS 1330272 |
Data Editor is showing the wrong wo_id on the Utilization tab. |
|
IMS 1398371 |
The migration script for migrating from MES 5.3 to 6.0 generates the error "Cannot insert duplicate key in object 'dbo.job_history'." (multiple job positions starting at the same time). |
|
IMS 1427402 |
The user has an apostrophe in their name and cannot log into MES. |
|
IMS 1434375 |
An OS User was moved to a group other than local Administrator and can no longer log in to MES. |
|
IMS 1437263 |
The stored procedure sp_U_Job_Hour_History_RefreshQtysAndTimes takes more than a minute to complete. |
|
IMS 1440740 |
ItemProd.UpdateSpecific method cannot update created_at date. |
|
IMS 1441052 |
An arithmetic overflow error occurs when converting IDENTITY to data type int in the job_hour_history table (row_id now is Big_Int). |
|
IMS 1503396 |
The migration script for migrating from MES 5.3 to 6.0 generates the error "Cannot insert duplicate key in object 'dbo.job_history'." (duplicate job_event records in the original database). |
|
IMS 1516792 |
Related to L00153800: Ending a paused job sets the job end utilization state when another job is still running. |
|
IMS 1555706 |
Inserting messages into the rejected message table fails in Russian time zones. |
|
IMS 1560981 |
Creating a new shift schedule interferes with existing calendar frequencies on other entities. |
|
IMS 1562267 |
Utilization Control does not update Category fields when changing downtime reason. |
|
IMS 1569379 |
Quality Web API Result (Post) to update an existing record does not flag the result as superseded. |
|
IMS 1577968 |
Web API for splitting the current utilization event (Split Next) generates 3 events instead of 2 events. |
|
IMS 1585235 |
IMS 1555706 for 5.3: Inserting messages into the rejected message table fails in Russian time zones. |
|
IMS 1589005 |
After creating a new bom_ver for a parent item that contains a sub-item, the BOM item operation links for the sub-item are removed. |
|
IMS 1592357 |
Setting OEE basis calculation to 1 (KPI per job) in the oee_exec table still calculates OEE KPIs by shift. |
|
IMS 1595508 |
Job_event.quantity is an integer when it should be a real. |
|
IMS 1605342 |
Reducing production of production counts recorded by the OCO fails in Operator or MDM Job Management Form because a different user is registered with the production vs reduction transaction. |
|
IMS 1613590 |
HF 577706 for MES 6.1: Undeploy/deploy of OCO causes rolling counters to improperly increment when using input source. |
|
IMS 1615207 |
Create Work Order from Process creates only one job for a process with a single operation and multiple entities. |
|
IMS 1626643 |
In a complex process with a multilevel BOM, setting a subitem as the produced item at an operation times out. |
|
IMS 1645833 |
OCO with push production on reset is recording the rollover value instead of just the incremental amount on reset command when the counter has an input source from I/O that also is changing to 0. |
|
IMS 1655505 |
Related to HF IMS 805244: Create Work Order from Process fails to create job BOM records. |
|
IMS 1677808 |
MES Web API Swagger JSON file for MDM updated to pass body parameters in the DirectAccess API (POST) within Work Tasks web API activity. |
|
IMS 1679737 |
Shift change process timing out - slow sp_U_TPM_Stat_RefreshTimes. |
|
IMS 1691063 |
Canceling a work order with jobs running on multiple job positions only cancels the job on job position 0. |
|
IMS 1698736 |
Cannot set the produced item for an operation in a process with complex BOMs. |
|
IMS 1729228 |
OEE KPI Control generates an error when the OEE value equals 0. |
|
IMS 1735473 |
Occasionally sample status stays "Ready" even when results have been recorded. Similar to HF L00145710. |
|
IMS 1747702 |
MES Web API to retrieve utilization records missing spare and category fields. |
|
IMS 1758256 |
HF 560891 for MES 6.2: Shifts are not changing on some entities tracking labor. |
|
IMS 1758257 |
HF 564097 for MES 6.2: Ending multiple jobs at one time takes a long time. |
|
IMS 1758342 |
HF 539797 for MES 6.2: Create WO from Process fails if the first operation includes a specification and the next operation has multiple entities. Cannot insert duplicate key in object 'dbo.job_spec'. |
|
IMS 1776370 |
Migration from MES 5.0 to 6.2 generates unique key constraint errors on job_history table. |
|
IMS 1781018 |
Continuation of HF 1747702: MES Web API to retrieve utilization records missing spare and category fields. |
|
IMS 1786715 |
In MES Client, the Add Frequency Link dialog stops populating when editing Sample Plans after opening and closing it multiple times. |
|
IMS 1791526 |
HF 1679737 for MES 6.2: Shift change process timing out - slow sp_U_TPM_Stat_RefreshTimes. |
|
IMS 1808716 |
Related to HF 1691063: MES Web API does not pause jobs running on multiple job positions; it can only pause the job at job position 0. Fix also includes changes from HF 1691063. |
|
IMS 1839546 |
After migration to MES 6.2, the job_hour_history table might not include production counts from AddProdPostExec if the timestamp doesn't match the job record. |
|
IMS 1847823 |
With large amounts of data within an hour, Purge process times with query size set to 1 hour. |
|
IMS 1853100 |
Related to HF 1691063: MES Web API does not end jobs running on multiple job positions; it can only end the job at job position 0. |
|
IMS 1860171 |
Cannot set the produced item for an operation in a process when the operation name is greater than 10 characters. |
|
IMS 1869589 |
HF 1735473 for MES 6.2: Occasionally sample status stays "Ready" even when results have been recorded. Similar to HF L00145710. |
|
IMS 1875623 |
Item Inventory Add incorrectly defaults status_cd to grade_cd in the stored procedure. |
|
IMS 1877180 |
MES Client crashes when opening item specifications if the user’s access level is NULL. |
|
IMS 1882057 |
vw_prod_events is much slower to execute compared with MES 2014. |
|
IMS 1885754 |
Item consumption from a storage entity with ‘Multiple lots/items stored here become indistinguishable' does not set the segment_requirement_id and segment_response_id fields in the item_cons table. |
|
IMS 1886463 |
Cannot register an application with AIM to call the MES Web API through a service-to-service token. |
|
IMS 1891768 |
Cannot edit entity attributes in the MES Web Portal. |
|
IMS 1903067 |
A new OS user cannot use MES Web API functions in Enterprise Console if they don't log in to the MES provider or MES Client application first. |
|
IMS 1905658 |
An arithmetic overflow error occurs in the stored procedure that calculates statistics when characteristics have very large sample sizes. |
|
IMS 1905962 |
Cloning a job does not transfer the serial_no_source field to the cloned job. |
|
IMS 1953213 |
When there are multiple OCOs with storage enabled on an engine, restarting the engine might leave some OCOs in Connecting status. |
|
IMS 1985700 |
On a French OS with comma as the decimal separator, MES QualityCharacteristicDetail Report generates the error "Subreport could not be shown" even with the correct security setting. |
|
IMS 2007701 |
Control rule violations are triggered with first result instead of waiting for the minimum sample size before evaluating control rules. |
|
IMS 2011639 |
Utilization group spare fields are not loaded in the MES Client editor. |
|
IMS 2030255 |
Modifying the start time of the shift schedule for the active shift to an earlier time is updating the current shift's start time, causing an overlap with a previous shift. |
|
IMS 2060346 |
The JobExec.AddConsDirect method logs created_at_local in the server time zone instead of the entity's site time zone. |
|
IMS 2070351 |
job_bom Spare fields are truncated when creating WO from process, splitting, or cloning a job |
|
IMS 2072146 |
The JobExec.AddProd method does not populate rmLotNo and rmSublotNo. |
|
IMS 2076937 |
A pulled sample transitions from In Progress to Ready when the expiration time elapses instead of transitioning to Late. |
|
IMS 2086178 |
Duplicate key error when setting the produced item for a process with complex routing. |
|
IMS 2089008 |
The SRO attributes RecentSampleX.SampleStatus and .ControlRuleViolation have a 10-second delay. |
|
IMS 2141338 |
HF 1330272 for MES 6.2: Data Editor is showing the wrong wo_id under the Utilization tab. |
|
IMS 2160659 |
Calling Pause Job with no job information (only job position) fails to pause the job. |
|
IMS 2160919 |
Required finish time for jobs created from a process with two initial operations do not match. |
|
IMS 2198972 |
Shift breaks are missing in the shift_to_go table for shifts that span across midnight. |
|
L00143038 |
Upgrades will fail if a table with a same name but different schema exists in MES database. |
|
L00149773 |
expiry_date column is recorded in local time only. |
|
L00149839 |
Milliseconds are not stripped off from the created_at_local and created_at_utc fields in the item_prod table. |
|
L00151587 |
Sample generation offset automatically shifts after midnight - Added new Start Delay option for Calendar Frequency. |
|
L00152300 |
When MES Service is changing shifts for a site not in the same timezone as where it is running, the records in shift_history are being created either before or after they should be. |
|
L00152573 |
Creating an instance of Sample Recording Object (SRO) logs unhandled errors when there is a default Area defined. The work around is to not have a default area or to ignore the messages. |
|
L00152703 |
Slowness in calling the API Prod.ItemProcessLink.Add method after many items and BOMs are linked. |
|
L00153893 |
The ItemInv.Add method does not accept NULL for grade and state - Method marked as obsolete and documentation improved. |
|
L00155839 |
Memory leak in Internet Explorer11/MS Edge when staying on a collection page such as line collection or work order collection. This is a Microsoft known issue and is addressed in the Chromium version of Edge. |
|
L00157474 |
Incorrect timestamp values are recorded to the job_event table when recording backflush consumption. |
|
L00157709 |
Setting 'Log storage entity changes' is not logging changes to spare_intx in the storage_ent_transfer table. |
|
L00158123 |
The following properties of the imported OMI apps cannot be saved in the OMI configuration (fixed in OMI 2020 R2):
|
|
L00158991 |
The Prod.Sublot.Rename method does not work when there is inventory. |
|
L00159022 |
Using PEM attributes in the OCO objects to report production/consumption for the same jobs on different entities at the same time results in not being able to stop the second job. |
|
L00159062 |
Jobs running for over a month take a long time to end and can time out. |
|
L00159144 |
Users are unable to log in to MES Client when one of the OS Groups to which the user belongs is deleted. |
|
L00159262 |
HF L00159062 for MES 6.1: Jobs running for over a month take a long time to end and can time out. |
|
L00159359 |
Pausing/suspending a job in the MES Client Job Queue does not update certain fields in the job and job_history tables. |
|
L00159432 |
Deploying OCO with a PEM instance that references 'MyContainer' causes warnings in the logger. |
|
L00159500 |
OCO Job attributes are stuck in the initializing state after a reboot. |
|
L00159604 |
MES Client APR will crash if an archive job is created and then the system parameter for the Archive Root Directory is changed. |
|
L00159669 |
When selecting an entity class in MES Client, the attributes are not updated. |
|
L00159775 |
Related to CR L00159262: Changing the utilization event for an entity that has been in the same state for over a month takes 1 minute. |
|
L00159891 |
When production is recorded during the first seconds of a new shift (shift change in progress), the shift information logged is for the previous shift, not the new one. |
|
L00159969 |
On a Terminal Server node, the MES middleware periodically denies connections and fails to record or read data. |