Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Manufacturing Execution System

MES Settings Affected When the System Management Server HTTPS Port Is Changed

MES Settings Affected When the System Management Server HTTPS Port Is Changed

  • Last UpdatedMay 01, 2023
  • 1 minute read

If the System Management Server or common platform HTTPS Port number is changed, the following MES components are affected and need to be reconfigured in the post-install Configurator.

DB/MW Communication

Middleware Proxy

  • If the System Management Server and MES middleware are on the same node and the HTTPS Port number is changed, change the proxy HTTPS Port number to match it and reconfigure the Middleware Proxy component.

  • If the System Management Server and MES middleware are not on the same node and the common platform HTTPS Port number for the MES middleware node is changed, change the proxy HTTPS Port number to match it and reconfigure the Middleware Proxy component.

See Configuring the MES Middleware Proxy.

Web Portal

If the System Management Server HTTPS Port number is changed, change the AIM HTTPS Port number to match it and reconfigure the Web Portal component.

See Configuring the MES Web Portal Component.