MES Settings Affected When the System Management Server HTTPS Port Is Changed
- Last UpdatedMay 01, 2023
- 1 minute read
If the System Management Server or common platform HTTPS Port number is changed, the following MES components are affected and need to be reconfigured in the post-install Configurator.
DB/MW Communication
-
If the System Management Server HTTPS Port number is changed, on the AVEVA Identity Manager tab change the AIM HTTPS Port number to match it and reconfigure the DB/MW Communication component. See Configuring AVEVA Identity Manager Client Registration.
-
If the System Management Server and MES middleware are on different nodes and the common platform HTTPS Port number is changed on the MES middleware node, reconfigure the DB/MW Communication component on that node. See Reconfiguring the DB/MW Communication Component If the Common Platform HTTPS Port Number Is Changed.
Middleware Proxy
-
If the System Management Server and MES middleware are on the same node and the HTTPS Port number is changed, change the proxy HTTPS Port number to match it and reconfigure the Middleware Proxy component.
-
If the System Management Server and MES middleware are not on the same node and the common platform HTTPS Port number for the MES middleware node is changed, change the proxy HTTPS Port number to match it and reconfigure the Middleware Proxy component.
See Configuring the MES Middleware Proxy.
Web Portal
If the System Management Server HTTPS Port number is changed, change the AIM HTTPS Port number to match it and reconfigure the Web Portal component.