Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Manufacturing Execution System

u Chart

  • Last UpdatedMar 19, 2016
  • 2 minute read

The following table contains the formulas used to calculate LCL and UCL for a chart point.

The example in the table illustrates the control limits calculated for a sample size of 15.

Formula

Example

CL = uBar

LCL = uBar – (3 * ControlRuleVioUChartEq1)

UCL = uBar + (3 * ControlRuleVioUChartEq1)

where n is the actual sample size from the sample.

If LCL < 0, then LCL = 0; otherwise LCL

uBar = 0.55224

CL = 0.55224

LCL = 0.45378 – (3 * ControlRuleVioUChartEq2) = –0.02339

LCL = 0

UCL = 0.55224 + (3 * ControlRuleVioUChartEq2) = 1.12786

The following table shows example control limits calculated for each chart point.

Label

Chart Point (Defects Per Unit)

Count

Size

LCL

CL

UCL

Lower σ

Upper σ

1

0.2

3

15

0

0.552239

1.127863

0.184080

0.191875

2

0.888889

8

9

0

0.552239

1.295367

0.184080

0.247709

3

0.666667

10

15

0

0.552239

1.127863

0.184080

0.191875

4

0.4

6

15

0

0.552239

1.127863

0.184080

0.191875

5

0.133333

2

15

0

0.552239

1.127863

0.184080

0.191875

6

0.55

11

20

0.053734

0.552239

1.050744

0.184080

0.166168

7

0.6

9

15

0

0.552239

1.127863

0.184080

0.191875

8

0.333333

5

15

0

0.552239

1.127863

0.184080

0.191875

9

1.333333

20

15

0

0.552239

1.127863

0.184080

0.191875

TitleResults for “How to create a CRG?”Also Available in