Result data (measurement) is captured for each sample and its deviation from specification limits (if any).

The following table shows the result data (measurement) captured for each sample and its deviation from specification limits (if any).

Sample ID

Sample Time

Spec Name

Charac
teristic Name

Value No.

Value

Actual Sample Size

Is the Value Out of Spec Limits

Fraction Defective

6

11:15a

SpecD

No. of Dents

1

3

15

False

0.2

8

11:30a

SpecD

No. of Dents

1

10

15

True

0.66667

9

11:45a

SpecD

No. of Dents

1

6

15

False

0.4

10

12:00p

SpecD

No. of Dents

1

2

15

True

0.13333

12

12:15p

SpecD

No. of Dents

1

9

15

True

0.6

13

12:30p

SpecD

No. of Dents

1

5

15

False

0.33333

The following examples illustrate control limits calculated for a sample size.