Configure the gas meter Row Edit
- Last UpdatedApr 24, 2025
- 3 minute read

The following table describes fields on the gasmeter Row Details: Main Tab.
To configure the Main tab of the gasmeter Row Edit
-
Select Historical... to open the collect Table Edit dialog box that can be used to configure Historical data collection.
-
Optional: Define your Well unit. This field is used by Display Framework, a separately-acquired product.
-
Optional: Define the Display Order. This field is used for display purposes. It would only be used if the nomination information were being represented on a station template object. It is only relevant to systems that have this optional software component. Unless you specifically use the Display Framework, the value is not used, but the default value is zero (0).
-
Optional: Select enableUpEvents if you would like to trigger an Upload Meter Events command in instances when the protocol detects any split hour records. This will occur in addition to generating an event in the Event Summary. For more information about this field, refer to volume 2 of the RealTime Administrator documentation.
Note: enableUpEvents and enableUpAGA only function when used in conjunction with the Fisher Remote Operations Controller (ROC) or Extended Modbus (Xmodbus) protocols.
-
Optional: Select enableUpAGA if you would like to trigger an Upload Meter Parameter AGA command for the current gasmeter Run Number in instances where the protocol detects any split hour records. This will occur in addition to generating an event in the Event Summary. For more information about this field, refer to volume 2 of the RealTime Administrator documentation.
-
The Group field provides the group information associated with the gas meter. The information comes from AVEVA Measurement Advisor. For more information, refer to the AVEVA Measurement Advisor User documentation.
-
The Remote field provides the remote associated with the gas meter. The information comes from AVEVA Measurement Advisor. For more information, refer to the AVEVA Measurement Advisor User documentation.
-
In the Station field, enter the name of the station where your gasmeter is located. The Station field is not related to the Measuring Station object in AVEVA Measurement Advisor.
-
The Dataset field provides dataset information. The information comes from AVEVA Measurement Advisor. For more information, refer to the AVEVA Measurement Advisor User documentation.
-
Define the Base Message, which is used for alarms and events that are related to the gas meter.
-
The Run Number provides the run number for the gasmeter. The information comes from AVEVA Measurement Advisor. For more information, refer to the AVEVA Measurement Advisor User documentation.
-
The Meter Type provides the gasmeter type. The information comes from AVEVA Measurement Advisor. For more information, refer to the AVEVA Measurement Advisor User documentation.
-
The Local Timestamp indicates the local timestamp preference. The information comes from AVEVA Measurement Advisor. For more information, refer to the AVEVA Measurement Advisor User documentation.
-
The Contract Hour provides the field device contract hour. This information comes from AVEVA Measurement Advisor. For more information, refer to the AVEVA Measurement Advisor User documentation.
Note: Not all fields are applicable to the AVEVA Pipeline Operations for Gas application.