Remote Row Edit: Remote Schedule tab
- Last UpdatedApr 24, 2025
- 3 minute read
It is possible to schedule when AVEVA Measurement Advisor will make data requests using the Remote Schedule tab of the remote Row Edit dialog box.
The requests that are unique to AVEVA Measurement Advisor are as follows:
-
Download Meter Configuration. Downloads the meter run American Gas Association (AGA) configuration from RealTime to the Electronic Flow Measurement (EFM) device.
-
Download Active GQ. Downloads the last valid zone gas quality (GQ) from RealTime and sends it to an EFM device.
-
Download Default GQ. Download the default GQ configuration to a chromatograph's configuration area within a general-purpose flow computer.
This information comes from the GQ when the Analysis Source is configured as a Chromatograph. The values entered on the Chromatograph tab in AVEVA Measurement Advisor are sent to the Flow Computer.
-
Upload GQ Alarms. Uploads all of the outstanding GQ alarm logs to RealTime. This information is sent to AVEVA Measurement Advisor for further processing and display.
-
Upload GQ Configuration. Uploads all of the current AGA information from the EFM device to RealTime. This information is sent to AVEVA Measurement Advisor for further processing and display.
-
Upload GQ Current Conditions. Uploads all of the current conditions for the GQ from the EFM device to RealTime. This information is sent to AVEVA Measurement Advisor for further processing and display.
-
Upload GQ Daily History. Uploads all of the outstanding GQ history for all of the metering runs and gas analysis sources to RealTime. This information is sent to AVEVA Measurement Advisor for further processing and display.
-
Upload GQ Events. Uploads all outstanding GQ event logs recorded on the EFM device to RealTime. This information is sent to AVEVA Measurement Advisor for further processing and display.
-
Upload GQ Hourly History. Uploads all of the outstanding GQ hourly history for all of the metering runs and gas analysis sources to RealTime. This information is sent to AVEVA Measurement Advisor for further processing and display.
-
Upload Meter Alarms. Uploads all of the outstanding metering alarm logs to RealTime.
This information is sent to AVEVA Measurement Advisor for further processing and display.
-
Upload Meter Configuration. Uploads all of the current AGA information from the EFM device to RealTime. This information is sent to AVEVA Measurement Advisor for further processing and display.
-
Upload Meter Current Conditions. Uploads all of the the meter's current conditions from the EFM device to RealTime. The information is sent to AVEVA Measurement Advisor for further processing and display.
-
Upload Meter Daily History. Uploads all of the outstanding meter daily history for all of the metering runs and gas analysis sources to RealTime. This information is sent to Measurement for further processing and display.
-
Upload Meter Events. Uploads all of the outstanding metering event logs recorded on the EFM device to RealTime. This information is sent to AVEVA Measurement Advisor for further processing and display.
-
Upload Meter Hourly History. Uploads all of the outstanding metering hourly history for all metering runs and gas analysis sources to RealTime. This information is sent to AVEVA Measurement Advisor for further processing and display.