Table details for information sent to RealTime from AVEVA Measurement Advisor
- Last UpdatedApr 24, 2025
- 2 minute read
The below table outlines the database details for information that is sent to RealTime from AVEVA Measurement Advisor.
|
Internal Field Name |
Data Type |
Description |
|---|---|---|
|
Aga3.Cfg.d_orif_Tref |
double |
Orifice reference temperature (Tdr). |
|
Aga3.Cfg.isentropicExp |
double |
Isentropic exponent. |
|
Aga3.Cfg.lowFlowCut |
double |
Low flow cut-off mark. |
|
Aga3.Cfg.orificePlate |
GasM_AGA3Plate |
Orifice plate type. |
|
Aga3.Cfg.tapLocate |
GasM_AGA3TapLoc |
Tap location (upstream/downstream). |
|
Aga3.Cfg.tapType |
GasM_AGA3Tap |
Tap type. |
|
Aga3.Factors.Fa |
GasM_AGAFactor |
Orifice thermal expansion factor. |
|
Aga3.Factors.Fdpwl |
GasM_AGAFactor |
Differential pressure (DP) gravity factor |
|
Aga3.Factors.Fpfwl |
GasM_AGAFactor |
Flowing pressure gravity factor. |
|
Aga3.Factors.Y |
GasM_AGAFactor |
Expansion factor. |
|
Aga3.Factors.Zb |
GasM_AGAFactor |
Base compressibility factor. |
|
Aga3.Values.d_orifice |
double |
Orifice diameter (d). |
|
Aga3.Values.D_tube |
double |
Inside pipe diameter (D). |
|
Aga3.Values.Pa |
double |
Atmospheric pressure. |
|
Aga3.Values.pb |
double |
Contract base pressure. |
|
Aga3.Values.Tb |
double |
Contract base temperature. |
|
Aga3_92.Cfg.d_orif_ref |
double |
Meter tube internal diameter at the reference temperature. |
|
Aga3_92.Cfg.d_orif_Tref |
double |
Orifice reference temperature (Tdr). |
|
Aga3_92.Cfg.D_tube_Tref |
double |
Tube reference temperature (TDr). |
|
Aga3_92.Cfg.gasViscosity |
double |
Gas viscosity. |
|
Aga3_92.Cfg.isentropicExp |
double |
Isentropic exponent. |
|
Aga3_92.Cfg.lowFlowCut |
double |
Low flow cutoff mark. |
|
Aga3_92.Cfg.meterTube |
GasM_AGA3_92mat |
Meter tube material. |
|
Aga3_92.Cfg.orificePlate |
GasM_AGA3_92mat |
Orifice plate material. |
|
Aga3_92.Cfg.Pb |
double |
Base pressure. |
|
Aga3_92.Cfg.tapLocate |
GasM_AGA3TapLoc |
Tap location (upstream/downstream). |
|
Aga3_92.Cfg.tapType |
GasM_AGA3_92tap |
Tap type. |
|
Aga3_92.Cfg.Tb |
double |
Base temperature. |
|
Aga3_92.Factors.Fdpwl |
GasM_AGAFactor |
Differential pressure gravity factor. |
|
Aga3_92.Factors.Fpfwl |
GasM_AGAFactor |
Flowing pressure gravity factor. |
|
Aga3_92.Factors.Y |
GasM_AGAFactor |
Expansion factor. |
|
Aga3_92.Factors.Zb |
GasM_AGAFactor |
Base compressibility factor. |
|
Aga3_92.Values.Pa |
double |
Atmospheric pressure (required for super-compressibility calculation). |
|
Aga3_92.Values.d_orifice_ref |
double |
Orifice plate bore diameter. |
|
Aga3_92Liquid.density |
GasM_density |
Density configuration information. |
|
Aga3_92Liquid.productType |
GasM_PrdType |
Product type. |
|
Aga7.Cfg.kFactor |
double |
K factor |
|
Aga7.Cfg.lowFlowCut |
double |
Low flow cutoff. |
|
Aga7.Cfg.mtrFactor |
double |
Meter factor. |
|
Aga7.Cfg.pipeVolume |
double |
Linepack physical pipe volume. |
|
Aga7.Cfg.pulseCalc |
GasM_PulseCalc |
Pulse count calculation policy. |
|
Aga7.Factors.st |
GasM_AGAFactor |
Compressibility ratio factor. |
|
Aga7.Factors.PfPb |
GasM_AGAFactor |
Pressure compensated factor. |
|
Aga7.Factors.TbTf |
GasM_AGAFactor |
Temperature compensated factor. |
|
Aga7.Factors.ZbZf |
GasM_AGAFactor |
Zb/Zf (Fpv) where:
|
|
Aga7.Values.Pa |
double |
Atmospheric pressure. |
|
Aga7.Values.pb |
double |
Contract base pressure. |
|
Aga7.Values.Tb |
double |
Contract base temperature. |
|
APILiquid.meterType |
GasM_PulseType |
Pulse meter type |
|
AvgCalc |
GasM_AvgCalc |
Average calculation type for linepack meters. |
|
ContractHour |
GasC_ContractHr |
Provides information about the field device contract hour. |
|
calcEnergy |
oas_boolean_t |
Calculate energy for host-calculated meters. |
|
calcMass |
oas_boolean_t |
Calculate mass for host-calculated meters. |
|
calcVolume |
oas_boolean_t |
Calculate volume for host-calculated meters. |
|
description |
pntdescription |
Record description. |
|
dataset |
doas_dset_slot |
Associated dataset. |
|
DataSource |
GasM_DataSource |
Data source for the meter. |
|
EFMservice |
pntname |
Provides information about the Electronic Flow Measurement (EFM) Service from which this object originated. |
|
GeneralInfo.elevation |
double |
Meter elevation. |
|
GeneralInfo.fieldMeterNum |
pntname |
Field meter number. |
|
GeneralInfo.meterCalFactor |
double |
Meter calibration factor. |
|
GeneralInfo.statPresSet |
GasM_PresSet |
Static pressure setting. |
|
generateDailyHist |
oas_boolean_t |
Generate daily history for host-calculated meters. |
|
generateHist |
oas_boolean_t |
Generate hourly history for host-calculated meters. |
|
gqDist.dlEnable |
oas_boolean_t |
Is the automatic download enabled? |
|
group |
groupslot |
Group of responsibility. |
|
hcdpcalcs.doCalcs |
oas_boolean_t |
Do hydrocarbon dewpoint calculations? |
|
hostSrc |
GasM_HostSrc |
Host calculation input sources. |
|
name |
pntname |
Name of gasmeter. |
|
measureGqId |
int |
Provides information about the associated measurement gas quality (GQ) object ID. |
|
objectId |
int |
Provides information about the internal object identifier. |
|
rtu |
remoteslot |
Remote device (if applicable). |
|
runNumber |
short |
Provides information about the meter run number (if connected to a remote). |
|
SCompCalc |
GasM_SCompCalc |
Supercompressibility calculation type. |
|
timezone |
GMAS_tzenum |
Timezone code. |
|
tstampPref |
GasC_TStampPref |
Provides information about the local timestamp preference. |
|
unit_profile |
GasC_UnitProf |
Provides information about the unit profile for the meter. |
|
VolCalc |
GasM_VolCalc |
Volumetric calculation type. |
|
zoneGqId |
int |
Provides information about the associated zone GQ object ID. |