Gas quality table details

  • Last UpdatedApr 24, 2025
  • 2 minute read

The following table describes internal field names in the RealTime database (RTDB) gasquality table.

Internal Field Name

Data Type

Description

accessFlag

displayname

Provides the access flag information.

avgHasBadQuality

oas_boolean_t

HostAvg[].hour contains values with bad quality results.

cplusSpread.C10_Weight

double

Provides the C10 spread weight.

cplusSpread.C6_Weight

double

Provides the C6 spread weight.

cplusSpread.C7_Weight

double

Provides the C7 spread weight.

cplusSpread.C8_Weight

double

Provides the C8 spread weight.

cplusSpread.C9_Weight

double

Provides the C9 spread weight.

cplusSpread.CXPlusType

GasQ_CXSpread

Provides the Cx plus type.

cplusSpread.spreadCplus

oas_boolean_t

Indicates whether or not the Cplus should be spread.

curHostBuf

GasQ_DataArray

Provides the current host-calculated data.

disableCalc

oas_boolean_t

Indicates whether calculations are disabled for this point.

dlManlReq

internaltime

The time that the GQ download was manually requested.

DSTfallInfo

oas_utime_t

Provides the last packet time during Daylight Saving Time (DST) fall transition.

DSTstate

dst_state

Provides the field device's DST state.

EFMservice

pntname

Provides the Electronic Flow Measurement (EFM) service information from which this object originated.

failedLastCalc

oas_boolean_t

Indicates whether the last host-calculation failed.

flag

flags

Provides the record status flags.

gqDataEff

GasQ_DataArray

Provides the current effective GQ data (from EFM).

histBuf

GasQ_H_Data

Historical data buffer.

histBuf.dataArray

GasQ_HistArray

Provides the Historical data array information.

histBuf.histInfo

GasC_HistInfo

Historical data information.

histBuf.histInfo.lastDay

GasC_GmtType

Provides the time of the last historical daily reading.

histBuf.histInfo.lastDay.offset

short

Provides the offset to local timezone (minutes).

histBuf.histInfo.lastDay.time

unsigned int

Number of seconds since Jan 1 1970 12:00 A.M.

histBuf.histInfo.lastEvent

GasC_GmtType

Time of the last historical event reading.

histBuf.histInfo.lastEvent.offset

short

Offset to local timezone (minutes).

histBuf.histInfo.lastEvent.time

unsigned int

Number of seconds since Jan 1 1970 12:00 A.M.

histBuf.histInfo.lastHour

GasC_GmtType

The timestamp of last historical hourly reading upload.

histBuf.histInfo.lastHour.offset

short

The offset to local timezone (minutes).

histBuf.histInfo.lastHour.time

unsigned int

Number of seconds since Jan 1 1970 12:00 A.M.

hostAvg

GasQ_AvgArray

Host calculator gas composition averages.

lastCalcTime

internaltime

Provides the last calculation time.

lastHistTime

internaltime

Indicates the last time the history or averages were completed.

loFloCheck

GasQ_LoFlow

Low flow rate checking (host AGA).

loFloCheck.flowRate

rateslot

Flow rate through gas chromatograph.

loFloCheck.minFlow

double

Provides the minimum flow value for a valid heating value calculation.

manVal

GasQ_manValArry

Provides the manual override configuration.

ptnum

slot

Provides the slot number in database.

therm

HeatingValue

Provides the heating value.

therm.CalcType

GasQ_ThermCalc

Provides the thermal calculation type.

therm.Tm

double

Provides the molar reference temperature.