Configure the alarm time for missing nominations
- Last UpdatedApr 24, 2025
- 1 minute read
If the system does not find a nomination file during the check, it generates an alarm. The generated alarm appears with the following message: missing the next <NameOfCycle> nomination.
You can configure the time that the system checks for the next nomination file, prior to the start of the next nomination cycle, by executing the following procedure.
To configure the alarm time for missing nominations
-
As required, copy the RealTime_GCN.json setting file from the source directory to the target directory as follows:
-
Source: %DNAInstallRoot%\AVEVA\DNA\RealTime\config\Settings\RealTime_GCN.json
-
Target: %DNADataRoot%\AVEVA\DNA\RealTime\config\Settings\RealTime_GCN.json
-
-
In the target directory, open the RealTime_GCN.json setting file in the text editor of your choice.
-
Navigate to the following line and modify it as required:
"GCN_MISSING_NEXT_NOMINATION_ALARM_TIME": 45
In the example above, the value is "45" (the default time). In this case, if the cycle starts at 21:00 P.M., then the system performs the first check at 20:16 P.M.
-
Save the file.
-
Restart the RealTime Service.