AVEVA™ Simulation for Triconex™ Systems

Edit Source SRC1 Using the Data Entry Window (DEW)

  • Last UpdatedJun 30, 2020
  • 2 minute read
  1. In the "Tank Level Control" window, right-click "SRC1" and select Data Entry.

  2. In the "SRC1" DEW dialog box under the Basic tab, modify the parameters as listed below, and then click Apply.

    Pressure

    300 kPag

    Temperature

    395 K

    Water

    1 kg-mol

    Relative Elevation

    10 m

    Note: Parameters highlighted in red require values to run properly.

    Embedded Image (65% Scaling) (LIVE)

    Notice the Basic tab displays a blue check mark that indicates these parameters have been updated.

  3. Navigate to the Thermo tab. Note that a yellow box indicates a parameter that has a default value and may require a change. Under Phase Options / Internal phases, select Vapor Liquid and click Apply. A blue check mark should appear next to the Thermo tab.

    Embedded Image (65% Scaling) (LIVE)

  4. Click OK to close the SRC1 DEW.