Configuring Key Points
- Last UpdatedJun 30, 2020
- 2 minute read
Key points can be added to the simulation to help determine the simulator status. These key points display in the IC and Backtrack summary page and, in Instructor Mode, along the top pane of the GUI. To configure key points, follow the instructions below.
-
Expand the Points library and select Dynamic Float. Click on the Tank Level Control flowsheet. When prompted, type in TTL1_L.
-
Right-click TTL1_L and click Edit.
-
In the Description field, type in Tank Level. Change the Units Type to Leng and set the Internal Units to m.

-
Repeat these steps to create a total of five points.
Point Name
Description
Units Type
Internal Units
TTL1_L
Tank Level
Leng
m
VTL1_L
VTL1 Lift
Frac
percent
S1_W
Inlet Flow
MassRate
kg/sec
S2_W
Outlet Flow
MassRate
kg/sec
MTL1_SPEED
Motor Speed
Rotation
rpm
-
Expand the Utilities library and select Miscellaneous Equation. Click on the Tank Level Control flowsheet.

-
Type in the name KEYPOINTS.
NOTE: The name of the Miscellaneous Equation object MUST be KEYPOINTS.
-
Right-click on KEYPOINTS and select Edit.

-
Set the OUT size to 5.

-
Assign values to the key points as shown in the following image. Click OK to close the dialog box and save the changes.