Historian issues
- Last UpdatedJan 07, 2025
- 2 minute read
|
Issue Number |
Description |
|
IMS 3541417 |
After upgrading a node that contains both Application Server and Historian from System Platform 2020 to System Platform 2023 R2 SP1, a required .DLL file is not installed. IMS 3540900 and IMS 3519786 are related to this issue, and the same general information applies to all three issues. Workaround 1: Uninstall System Platform, then do a fresh install of System Platform 2023 R2 SP1. Note: Be sure you have good backups of your Historian databases and Application Server galaxies before uninstalling System Platform. Workaround 2: Back up your Historian databases and Application Server galaxies and restore on a new node with System Platform 2023 R2 SP1. Workaround 3: Install System Platform 2023 R2 SP1 on a VM, then:
|
|
IMS 3540900 |
After upgrading a node that contains both Application Server and Historian from System Platform 2020 to System Platform 2023 R2 SP1, a required .DLL file is not installed. IMS 3541417 and IMS 3529786 are related to this issue, and the same general information applies to all three issues. Workaround 1: Uninstall System Platform, then do a fresh install of System Platform 2023 R2 SP1. Note: Be sure you have good backups of your Historian databases and Application Server galaxies before uninstalling System Platform. Workaround 2: Back up your Historian databases and Application Server galaxies and restore on a new node with System Platform 2023 R2 SP1. Workaround 3: Install System Platform 2023 R2 SP1 on a VM, then: 1. Copy the following files from the VM:
|
|
IMS 3523525 |
After upgrading a node that contains both Application Server and Historian from System Platform 2020 R2 to System Platform 2023 R2 SP1, some files that should no longer be present on the node remain. This only occurs if both Application Server and Historian are installed. No user action is required. |
|
IMS 3519786 |
After upgrading a node that contains both Application Server and Historian from System Platform 2023 to System Platform 2023 R2 SP1, some files that should no longer be present on the node remain. This only occurs if both Application Server and Historian are installed. No user action is required. |