Minimum SMS architecture using an authentication provider
- Last UpdatedAug 12, 2025
- 1 minute read
This system design uses a single node for user authentication. This design does not provide for redundancy.
Node 1 - SMS on the GR or other deployed platform
In this minimum architecture, the System Management Server is installed on the GR node.
-
On the System Management Server tab of the Configurator, select the option "This machine is the System Management Server."
-
On the Authentication Provider tab:
-
Select the checkbox to "Configure this machine to provide SSO via an external Authentication Provider."
-
Configure the token host.
-
Node 2 though n
-
On the System Management Server tab of the Configurator, select the option "Connect to an existing System Management Server."
-
Select node 1 as the existing SMS node.
-
For the option to configure the node as a redundant SSO Server, leave the checkbox unchecked .
-
-
On the Authentication Provider tab:
-
Select the checkbox to "Configure this machine to provide SSO via an external Authentication Provider."
Note: Since this node is not a redundant authentication provider, the fields to configure a token host are not shown.
-