Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

Unified Supply Chain Process Model Manager

Add recut property symbol

  • Last UpdatedAug 14, 2026
  • 1 minute read

  1. To use the recut value of a property select Add Recut Property as a Symbol

  2. Enter the Name for the variable in the Symbol field (this will be used to refer to the property in the formula), and use the Property Control to select the required property.

  3. Select a radio button to define from which stream the property value is calculated:

    • Measured on Calculation Stream - uses the property value for the stream the calculation is being applied to (for example, if applying the formula to light and heavy naphtha, for the light naphtha stream the calculation would use the RON of the light naphtha stream, and for the heavy naphtha stream the calculation would use the RON of the heavy naphtha stream)

    • Measured on Whole Crude - uses the property value for the whole crude

    • Measured on Stream - select the stream from which the property value should be calculated, this value will always be used in the calculation (for example, if light naphtha was selected as source stream, but the user calculation was applied to heavy naphtha, the light naphtha RON value would still be used in the calculation).