Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Operations Management Interface

Enable non-secured port for HTTPS auto-redirect

  • Last UpdatedDec 09, 2024
  • 1 minute read

The InTouch Access Anywhere Secure Gateway Web server listens on port 80 by default. This way, HTTP references to the server will automatically redirect to the HTTPS URL.

Note: This feature only works if the Secure Gateway is listening on port 443. If it is configured to use any other port, the HTTP automatic redirect is not supported.

To enable this feature, select the option: Enabled non-secured port for HTTPS auto-redirect (see below).

Enable a non-secured port for an HTTPS auto-redirect

Configure this feature in the EricomSecureGateway.exe.Config file using: <add key="EnableNonSecuredPortForHttpsAutoRedirect" value="false" /> in the <appSettings> section.