The RCFUPDATE command is usually given immediately after Databases (DBs) have been reconfigured. The index can be saved to a file when the reconfiguration has been completed, to be used at a later date.

The commands are DUMP to save to a file, and LOAD to load a file. For example:

LOAD /DUMP1

FROM DB MASTER/DESIGN

TO DB MASTER/DESNEW

RCFCOPY ALL

RECONFIGURE

DUMP /DUMP2

These commands will read an existing reference number index from file /DUMP1, add the reference number pairs from the specified reconfiguration to it, and then write the index out again to the file /DUMP2.

If a number of DBs have been reconfigured, the dump file will record the cross-reference index for all of them.

The LOAD command replaces the current index. The command LOAD APPEND appends the table to the current index.