Rebuilding All PML File Indexes
- Last UpdatedOct 21, 2022
Note:
This process can take some time, and it is possible that if another user gives the
command at the same time, the index files may not be re-built properly. Hence it is
recommended that this command should only be used when necessary. System Administrators
are advised to maintain firm control over the directories in the PMLLIB search path by removing write access for most Users.
The following command scans all the files in all the directories in your PMLLIB path, and updates the pml.index files.
pml rehash all
From the release of AVEVA Administration 1.9.4, the pml.index file is no longer required or produced and is now managed in memory and any changes to PML files and subsequent issuing of the pml rehash command will update the memory.
Note:
Currently the only other product(s) using this method of pml index management is the
AVEVA Engineering 15.5 series and above.