Heat and mass balance list datasheet reports
- Last UpdatedJul 10, 2026
- 1 minute read
Configure the database view and database view set correctly before you create a Heat and Mass Balance (H&MB) list datasheet.
The H&MB list datasheet supports Engineering, Simulation, and Functional data.
To display FEED stream data in a datasheet, add the following items to the datasource:
-
A flowing component database view.
-
A database view set that contains:
-
Streams view
-
Material Flow Specification view
-
Material Flow Bulk view
-
Material Flow Liquid Bulk view
-
Material Flow Phase view
-
The datasource must contain the following:
-
A flowing component view.
-
A database view set that includes the required views and column relationships.
Create column relations between these views as shown in the configuration diagram.