  • 2 minute read

TaskUpdateConfig is a built-in function that updates a runtime task in order to reload a task worksheet during project run time.

Function

Group

Execution

String Exp.

Windows

Windows Embedded

IoT View

Thin Clients

Mobile Access

TaskUpdateConfig

Module Activity

Asynchronous

No

Supported

Not supported

Not supported

Not supported

Not supported

Syntax

TaskUpdateConfig(strTask,numWorksheet)

TaskUpdateConfig ( { strTask | " { Math | Scheduler | Script | TCPClient | OPCUAClient } " } ,numWorksheet)

strTask

The name of the runtime task to be updated. It must be one of the following string values:

Value

Description

Math

Math worksheets, which are executed as part of the Background Task

Scheduler

Scheduler worksheets, which are executed as part of the Background Task

Script

Script worksheets, which are executed as part of the Background Task

XDB

Database/ERP

OPCUAClient

OPC UA Client

TCPClient

TCP/IP Client

For more information, see Runtime Tasks.

numWorksheet

The number of the worksheet to be reloaded.

Return value

This function returns one of the following possible values:

Value

Description

0

Failure (for example, invalid task name, specified task not started, specified worksheet not found)

1

Success

Notes

If you use the project development environment to edit and then save a task worksheet in a project running locally, that worksheet is automatically and immediately reloaded by the project. You do not need to use this function to reload the worksheet.

This function is used to reload worksheet files that have been created or edited outside the project development environment and then manually added to the project folder. As such, it is not intended for typical users of this software. If you want more information about how to use this function, please contact your software distributor.

Worksheet files must be located in the project folder, and each worksheet file name must include both the type of worksheet and the worksheet number. For example, Math worksheet number 3 is saved at the following location:

<project name>\Config\MATH003.MAT

The specified task must be started before this function is called; calling this function does not start the specified task. If the task was not automatically started when the project was run, you can use either the Runtime Tasks command or the StartTask function to manually start the task.

Examples

Update the Math task in order to reload worksheet number 3 (MATH003.MAT):

TaskUpdateConfig("Math",3)