Gets a the value of a variable in the Windows registry.

Function

Group

Execution

String Exp.

Windows

Windows Embedded

IoT View

Thin Clients

Mobile Access

GetRegValue

System Info

Synchronous

Yes

Supported

Supported

Not supported

Not supported

Not supported

Syntax

GetRegValue( numMainKey, strKey, strValueName )

numMainKey

Numeric tag with the following possible values:

0

HKEY_LOCAL_MACHINE

1

HKEY_CLASSES_ROOT

2

HKEY_CURRENT_USER

3

HKEY_USERS

4

HKEY_CURRENT_CONFIG

5

HKEY_PERFORMANCE_DATA

strKey

Path where the value is located in the Main Key.

strVariableName

Name of the variable to get. The maximum length is 255 characters.

Returned value

If the function succeeds, then the function returns the variable value. Otherwise one of the following error codes will be returned:

-1

Invalid number of parameters or invalid Main Key.

-2

Variable type is not supported. You can only read DWord or String values from the registry.

-3

Failed to read the variable value; verify that you have the proper security rights.

Examples

Tag Name

Expression

Tag

GetRegValue( 0, "HARDWARE\DESCRIPTION\System", "SystemBiosDate" ) // Returned value = "08/14/03"

Tag

GetRegValue( 2, "Control Panel\Current", "Color Schemes" ) // Returned value = "Windows Standard "