During project runtime, a trend control has its own built-in interface that the operator can use to change how trends are displayed. This section describes the major parts of the interface and how they are used.

Trend control runtime interface

Toolbar

Command/Tool

Icon

Description

Activation Tag

Run

Run icon

Sets the trend control to Run Mode (also known as Online Mode). In this mode, the X-axis continues to scroll with the passage of time and the trends are updated with current tag values.

0 = stop trend

1 = run trend

The Activation Tag is only one for both Run and Stop commands and it is configured on the "Run/Stop" field

Stop

Stop icon

Sets the trend control to Stop Mode (also known as Historical Mode). In this mode, the X-axis is stopped and the trends display only historical data.

If decimation is enabled for one or more trends, the calculation and redrawing is done only in this mode.

0 = stop trend

1 = run trend

The Activation Tag is only one for both Run and Stop commands and it is configured on the "Run/Stop" field

Period

Period icon

Opens a dialog which can be used to modify the X-axis scale main settings.

1 = open dialog

Resets to 0 after open.

Window Zoom

Window Zoom icon

Allows the user to click on the trend graph and drag the cursor to select the area that must be visible when the cursor is released.

This option is disabled when the Multiple Section option (for the Y scale) is active.

0 = disable zoom

1 = enable zoom

Resets to 0 after user input.

Horizontal Zoom

Horizontal Zoom icon

Allows the user to click on two points in the trend graph, defining the horizontal scale that must be available.

Vertical Zoom

Vertical Zoom icon

Allows the user to click on two points in the trend graph, defining the vertical scale that must be available.

This option is disabled when the Multiple Section option (for the Y scale) is active.

Zoom In

Zoom In icon

Zooms in (that is, halves the current X and Y scales) each time the user clicks the tool.

1 = execute command

Resets to 0 after execution.

Zoom Out

Zoom Out icon

Zooms in (that is, doubles the current X and Y scales) each time the user clicks the tool.

Cancel Zoom

Cancel Zoom icon

Cancels the current zoom and returns the trend graph to its original scale.

Legend Properties

Legend Properties icon

Opens a dialog which can be used to modify the Legend main settings.

Pen Style

Pen Style icon

Opens a dialog which can be used to modify the pen style of the selected trend.

Add Pen

Add Pen icon

Opens a dialog which can be used to add a new trend to the trend control.

Remove Pen

Remove Pen icon

Removes the selected trend from the trend control.

Multiple Sections

Multiple Sections icon

Switches the Y scale between Multiple Sections (a section for each trend) and Single Section (all trend share the same Y scale section).

0 = Single Section

1 = Multiple Sections

Cursor

Cursor icon

Switches the cursor (ruler) between visible and hidden.

0 = Cursor hidden

1 = Cursor visible

Auto Scale

Auto Scale icon

Changes the Y axis scale to fit all values from the trends that are currently being monitored.

1 = execute command

Resets to 0 after execution.

Print

Print icon

Prints the current state of the trend control. (Historical data are not printed.)

SPC

SPC icon

Opens a dialog which can be used to show the statistical process control (SPC) information for the selected trend:

SPC Settings dialog

  • Draw Mode…

    • Shade: Draws the average value as a dashed line, and draws the min/max values and standard deviation as shaded areas.

    • Line: Draws the average value and standard deviation as dashed lines, and draws the min/max values as solid lines.

  • Show average: Show the calculated average of all of the trend's historical values.

    Note: When a value is not a number (NaN) — for example, when a tag is flagged as BAD quality — it is counted as 0 for the purpose of calculating the average.

  • Show min/max: Show the minimum and maximum historical values of the trend.

  • Show standard deviation: Show the standard deviation of the trend. A low standard deviation indicates that the actual value tends to stay close to the average; a high standard deviation indicates that the actual value tends to vary greatly from the average.

The tag's Bit properties (B0–B4) can be used to open the dialog and pre-select options:

  • tagname->B0

    • 1 = open dialog

      Resets to 0 after open.

  • tagname->B1

    • 0 = Draw Mode: Line selected

    • 1 = Draw Mode: Shade selected

  • tagname->B2

    • 0 = Show average cleared

    • 1 = Show average selected

  • tagname->B3

    • 0 = Show standard deviation cleared

    • 1 = Show standard deviation selected

  • tagname->B4

    • 0 = Show min/max cleared

    • 1 = Show min/max selected

Note: Activation tags are configured in the trend control's object properties.

For more information, see Toolbar dialog.

Time bar

The time bar displays the start date/time and end date/time of the graph, or in other words, the period of the X axis. For more information, see Axes dialog.

If you have configured the trend control to display historical data from a batch file, you can change these dates and times during project run time and therefore increase or decrease the period of the graph. The longer the period, the more data the graph will display but at lower resolution. The shorter the period, the less data the graph will display but at higher resolution. This is similar to using the Horizontal Zoom tool.

Note: If you enter a date (start or end) before 01/01/2000, it will be automatically adjusted to 01/01/2000. And if you enter a date (start or end) after the current date, it will be automatically adjusted to the current date.

All dates must be formatted according to the current date format. For more information, see About the date format and how to change it.

Legend

Command

Icon

Description

Selection

Launches a dialog, where the user can replace the data point associated with the selected trend on the legend

Remove

Removes the selected trend from the trend control

Hide

When checked, the selected trend is visible; otherwise, it is hidden.

Pen Style

Launches an embedded dialog, where the user can modify the pen style of the selected trend.

Scale

When this box is checked, the Y axis scale is visible; otherwise, it is hidden. The scale can be hidden only when the Multiple Sections option is off.

For more information, see Legend dialog.

In This Topic