Designate Save History Information

  • Last UpdatedOct 29, 2024
  • 1 minute read

Use the Save History Control/Status Activity and Parameter Status check boxes to configure the type of phase activity that is to be stored in the History database. All data stored in the History database is stamped with the time and date. You can enable both check boxes if required. Using this history feature is optional.

To enable Save History options

  1. In the Edit Phases dialog box, enable the Control/Status Activity check box, the Parameter Status check box, or both.

    • Enable the Control/Status Activity check box to include all phase control and status bit transitions.

    • Enable the Parameter Status check box to include (when the phase is done) all parameter element values, control button activity, and phase instructions.

  2. Click Change.