  • 1 minute read

If you are using manual operation and have created and configured tags for the Target, Hi Dev, or Low Dev elements in your process model, you must be aware that the elements shown in the Batch Display, regardless of how they are configured in the process model database may not appear as you expect. For example, in your process model, you may have created a tag for an analog data class. For the Hi Dev element, you may have disabled the Edit Allowed attribute. When you schedule and run a phantom batch, the Edit Allowed attribute of the tag is enabled. The Batch Display therefore allows the Hi Dev value to be edited even though your process model was configured to disable it.

The following table shows the relationship between each tag data class and element, and how the Enable Display and Edit Allowed attributes are forced in Batch Display.

Tag Data Class and Element

Tag Attributes:

Enable

Edit Allowed

Analog

Target

Hi Dev

Low Dev

Always

Always

Discrete

Target

N/A

N/A

Always

Always

String

Target

N/A

N/A

Always

Always

Enumeration

Target

N/A

N/A

Always

Always