Known Issues
- Last UpdatedJan 10, 2025
- 8 minute read
This section describes important known issues.
-
Installation Issues
-
Other Issues
Installation Issues
|
2456284 |
AVEVA Batch Management application messages are not logged in SMC until the node is rebooted after installation. |
|
616969 |
Configuration of the History Server feature fails when you upgrade InBatch History Server to InBatch version 11.5.1 from versions prior to InBatch 11.0. Before proceeding with the upgrade, ensure that you delete all SQL Jobs related to Archive\Purge\Restore. Prior to InBatch 11.0 version, any SQL Agent jobs (Archive\Purge\Restore jobs) created in InBatch History Server may have been associated with BatchAdminUser, BatchReportAdmin, or BatchUser role. These user roles have been removed in 11.0 release. |
|
L00107356 |
Due to the large number of services running on Foxboro DCS platforms, the installation program should check the value of the SessionViewSize registry setting. It is likely that this registry value does not exist and will need to be created. If you ever notice that services unexpectedly fail to start, the value of this setting may be too small. Follow these steps:
|
|
L00127339 |
Machine names in redundant systems must be 12 characters or less. |
|
IMS 3609976 |
The I/O tag write failures may occur when AVEVA Batch Management 2023 R2 is installed on top of System Platform 2023 R2. Workaround: Apply the Hotfix 3609976. |
|
IMS 3647440 |
Users will be unable to log in to the System Platform IDE using the AVEVA Connect SSO configuration if Batch Management 2023 R2 is installed on top of System Platform 2023 R2. Workaround: Upgrade System Platform to 2023 R2 SP1. |
|
IMS 3647457 |
The InTouch web client does not display the deployed object's tag values at runtime when Batch Management 2023 R2 is installed on top of System Platform 2023 R2. Workaround: Upgrade System Platform to 2023 R2 SP1. |
|
IMS 3647498 |
Error "LicAPI.Loader.Core" and warning "vcp.services.onprem.frontdoo'" are logged in the SMC logger when deploying the AVEVA Batch Management 2023 R2 OMI Web View App on System Platform 2023 R2. Workaround: Upgrade System Platform to 2023 R2 SP1. |
|
IMS 3647528 |
Configuring "Microsoft Entra ID" as the Federated Identity Provider in the configurator will cause the System Platform IDE to crash when adding new roles, if Batch Management 2023 R2 is installed on top of System Platform 2023 R2. Workaround: Upgrade System Platform to 2023 R2 SP1. |
|
IMS 3648047 |
You may observe an exception in the Event Viewer when stopping Batch Management Services (IBServ). This issue occurs on Windows 2019, 2022, and 2025 but does not affect functionality. |
|
IMS 3650140 |
If AVEVA Batch Management 2023 R2 is uninstalled from a system that also has other AVEVA products installed, the "System Management Server" and "Federated Identity Provider" features might revert to an unconfigured state. Workaround: Reconfigure the "System Management Server" and "Federated Identity Provider" features. |
|
IMS 3678006 |
Uninstalling AVEVA Batch Management 2023 R2 also removes the LicAPI (x64) feature when AVEVA System Platform 2023 R2 SP1 is installed. Workaround: Reinstall the AVEVA Enterprise Licensing Platform feature. |
|
IMS 3692747 |
The startup time for the AVEVA Batch Management 2023 R2 (v13.1) IBMX service is longer with System Platform 2023 R2 SP1. Workaround: Apply the Hotfix 3692747. |
|
IMS 3696628 |
The startup time for the AVEVA Batch Management 2023 R2 (v13.1) IBMX service is longer with System Platform 2023 R2. Workaround: Apply the Hotfix 3696628. |
Other Issues
|
IMS 2353338 |
Unknown Opcode Internal Error dialog box is displayed in AVEVA InTouch 2023 when Batch Management ActiveX application switches to runtime. Workaround: Apply AVEVA System Platform 2023 P01 Patch. |
|||||||||||||||||||||||||
|
1055512 |
Batch Management web client Icons and images are distorted in Mozilla Firefox browsers. Workaround: Do the following settings in the Firefox browser:
|
|||||||||||||||||||||||||
|
459424 |
Ensure that you adjust the InTouch application layouts to account for the new Formula column in the lists, if you are using GuiControl lists (ScheduleEdit.Schedule, BatchView.Batch, and BatchView.AllocationQueue). The width of other GUI Control lists may have also been increased to support better presentation of longer values. |
|||||||||||||||||||||||||
|
614956 |
SSRS report execution (i.e. when you open the report and click "View Report") displays a blank page in the Chrome browser. Workaround: To resolve this error, do the following:
|
|||||||||||||||||||||||||
|
L00077400 |
Editors are not opening on the AVEVA Batch Management development client. Workaround:
|
|||||||||||||||||||||||||
|
L00081552 |
Running Wonderware InBatch with Foxboro DCS components in a redundant configuration does not fail over when FoxDCSDriver is shut down. The following table shows the redundancy status on master/backup nodes when IBMX, IBCli, and FoxDCSDriver are stopped from the Runtime Services dialog box or when you end the process from the Task Manager.
|
|||||||||||||||||||||||||
|
L00082612 |
Custom-created reports that are populated to the batch report directory are not available for configuration and scheduling. Use the following steps to configure and schedule the custom reports. For example, suppose a report named "Custom Batch Detail" is populated in the list.
|
|||||||||||||||||||||||||
|
L00098867 |
When using the IBCli application, some I/O Servers or DAServers (including FS Gateway) may report an error about an "Unknown Watchdog" tag. This error is only reported when IBCli starts. However, the Watchdog tag still functions as expected. If you get the following errors from IBCli:
|
|||||||||||||||||||||||||
|
L00125348 |
If you use the Import Utility in the preview mode, warning messages are not shown. This is observed when the utility imports a Wonderware InBatch ModelDB, in which any of the following have duplicate names (case sensitive): processes, transfers, segments, units, connections, or phases. However, warning messages are shown when you perform an actual import. |
|||||||||||||||||||||||||
|
L00128201 |
When you run the cvtmaster for a second time, conversion fails. Workaround:
|
|||||||||||||||||||||||||
|
L00139186 |
Error and warning messages related to ReportQueueReader are logged in the SMC logger after you enable the Enhanced security mode using "aaConfigSQL" tool. Workaround: Ensure that the ServiceDB user (configured to run the InBatch ReportQueueReader service) has access to printers and has the privilege to print. |
|||||||||||||||||||||||||
|
1010526 |
Compatibility issues with Vijeo Citect 2016
|
|||||||||||||||||||||||||
|
1102209 |
The "History Admin" and the "Report Web" pages display the following error: Unable to contact Batch Host to determine if security is enabled. Check Batch Host and restart browser. This error is observed when you:
Workaround:
|
|||||||||||||||||||||||||
|
157908 |
When the BatchHistory database and Batch Management reports are in distributed nodes, Batch Management reports execution is failing with the error "An error has occurred during report processing. (rsProcessingAborted). Query execution failed for dataset 'BatchDetailData'. (rsErrorExecutingCommand). Login failed for user 'NT Authority\Anonymous Logon' ". Workaround: To overcome this error, do the following.
|
|||||||||||||||||||||||||
|
IMS 1700890 |
After upgrading Batch Management to the latest version and when you import the Batch model in IDE, the following error gets displayed: "Error in creating toolsets or templates Method not found". Workaround: To overcome this error, do the following.
|