Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ InTouch HMI

Available dotfields for tag types

  • Last UpdatedJul 29, 2024
  • 5 minute read

Each type of InTouch tag has a set of dotfields associated with its unique properties. The following table shows an alphabetical list of dotfields for all types of tags.

Dotfields

Tag Types

Memory

I/O

Indirect

Miscellaneous

Discrete

Integer

Real

Message

Discrete

Integer

Real

Message

Discrete

Analog

Message

Alarm Group

Hist Trend

Distributed Alarm Object / Controls

TagID

.Ack

.AckDev

.AckDsc

.AckROC

.AckValue

.Alarm

.AlarmAccess

.AlarmAckModel

.AlarmClass

.AlarmComment

.AlarmDate

.AlarmDev

.AlarmDevCount

.AlarmDevDeadband

.AlarmDevUnAckCount

.AlarmDisabled

.AlarmDsc

.AlarmDscCount

.AlarmDscDisabled

.AlarmDscEnabled

.AlarmDscInhibitor

.AlarmDscUnAckCount

.AlarmEnabled

.AlarmGroup

.AlarmGroupSel

.AlarmHiDisabled

.AlarmHiEnabled

.AlarmHiHiDisabled

.AlarmHiHiEnabled

.AlarmHiHiInhibitor

.AlarmHiInhibitor

.AlarmLimit

.AlarmLoDisabled

.AlarmLoEnabled

.AlarmLoInhibitor

.AlarmLoLoDisabled

.AlarmLoLoEnabled

.AlarmLoLoInhibitor

.AlarmMajDevDisabled

.AlarmMajDevEnabled

.AlarmMajDevInhibitor

.AlarmMinDevDisabled

.AlarmMinDevEnabled

.AlarmMinDevInhibitor

.AlarmName

.AlarmOprName

.AlarmOprNode

.AlarmPri

.AlarmProv

.AlarmROC

.AlarmROCCount

.AlarmROCDisabled

.AlarmROCEnabled

.AlarmROCInhibitor

.AlarmROCUnAckCount

.AlarmState

.AlarmTime

.AlarmTotalCount

.AlarmType

.AlarmUnAckCount

.AlarmUserDefNum1

.AlarmUserDefNum1Set

.AlarmUserDefNum2

.AlarmUserDefNum2Set

.AlarmUserDefStr

.AlarmUserDefStrSet

.AlarmValDeadband

.AlarmValue

.AlarmValueCount

.AlarmValueUnAckCount

.Caption

.ChartLength

.ChartStart

.Comment

.DevTarget

.DisplayMode

.Enabled

.EngUnits

.Freeze

.HiHiLimit

.HiHiSet

.HiHiStatus

.HiLimit

.HiSet

.HiStatus

.ListChanged

.ListCount

.ListIndex

.LoLimit

.LoLoLimit

.LoLoSet

.LoLoStatus

.LoSet

.LoStatus

.MajorDevPct

.MajorDevSet

.MajorDevStatus

.MaxEU

.MaxRange

.MaxRaw

.MinEU

.MinorDevPct

.MinorDevSet

.MinorDevStatus

.MinRange

.MinRaw

.Name

.NewIndex

.NextPage

.Normal

.NumAlarms

.OffMsg

.OnMsg

.PageNum

.Pen1 through .Pen8

.PendingUpdates

.PrevPage

.PriFrom

.PriTo

.Quality

.QualityLimit

.QualityLimitString

.QualityStatus

.QualityStatusString

.QualitySubstatus

.QualitySubstatusString

.QueryState

.QueryType

.RawValue

.ReadOnly

.Reference

.ReferenceComplete

.ROCPct

.ROCSet

.ROCStatus

.ScooterLockLeft

.ScooterLockRight

.ScooterPosLeft

.ScooterPosRight

.Successful

.SuppressRetain

.TagID

.TimeDate

.TimeDateString

.TimeDateTime

.TimeDay

.TimeHour

.TimeMinute

.TimeMonth

.TimeMsec

.TimeSecond

.TimeTime

.TimeTimeString

.TimeYear

.TopIndex

.TotalPages

.UnAck

.UpdateCount

.UpdateinProgress

.UpdateTrend

.Value(Tagname)

.Value(Windows Control)

.Visible

Dotfields can be categorized by their intended function. For more information about dotfield functional categories, see the following sections:

Category

See

Values and limits

Change the value limits of a tag.

Alarm parameters

Control alarm properties of tags and groups at runtime in AVEVA™ InTouch HMI Application Run Time.

I/O

Data access with I/O.

Distributed Alarm Object

Working with the Distributed Alarm Display Object.

Trend display

Trending tag data.

Window controls

Wizards

TitleResults for “How to create a CRG?”Also Available in