In the digital state table, the primary key is SET. Use the NEWSET attribute to change the value of the primary key:

(Ls - ) piconfig> @table pids
(Ls - PIDS) piconfig> @mode list
(Ls - PIDS) piconfig> @ostructure set
(Ls - PIDS) piconfig> @select set=*
(Ls - PIDS) piconfig> @endsection
SYSTEM
BATCHACT
PHASES
MODES
VALVESTATESET
(Ls - PIDS) piconfig> @mode edit
(Ed - PIDS) piconfig> @istru set,newset
(Ed - PIDS) piconfig> ValveStateSet,NewValveStateSet
(Ed - PIDS) piconfig> @mode list
(Ls - PIDS) piconfig> @ostructure set
(Ls - PIDS) piconfig> @select set=*
(Ls - PIDS) piconfig> @endsection
SYSTEM
BATCHACT
PHASES
MODES
NEWVALVESTATESET