Refit
- Last UpdatedDec 01, 2022
- 2 minute read

In case a bore size inconsistency has occurred, the Refit function can be used. This can for example happen when a reducer is inserted and the Propagate autofit setting is set to False. In the example above, the reducer has an input bore size of 100 and output of 80 while the downstream valve has a bore size of 100. Such inconsistencies can be found by using the Consistency Check function.

By using the refit function available on the shape right click menu, the specification reference for the valve will be re-selected using the upstream bore size.

After the Refit command has been performed, the valve now has a correct bore size and specification reference.
Depending on the propagation settings, the action will propagate downstream to a varying degree.