Schematic Instrument Reference Type (SCIRTY)
- Last UpdatedDec 01, 2022
- 1 minute read
The type of SCIRTY connection (that means, electrical, infrared, Bluetooth, ZigBee, hydraulic .) can be determined by using the SCIRTY attribute. This attribute is an array and has the same size as SCIREF.
The available pseudo-attributes for querying SCIRTY are described below:
|
SCIRLT |
Pseudo attribute returning all connection types that are linked with SCIREL. |
|
SCIERT |
Pseudo attribute returning all connection types that are linked with SCEIRE. |
|
SCIPRT |
Returns a list of connection types for process connections of Actuator or Offline Instrument (connection types from SCIRTY which are corresponding with elements returned by SCIPRE). |
|
SCIIRT |
Returns a list of connection types for instrumentation connections of Actuator or Offline Instrument (connection types from SCIRTY which are corresponding with elements returned by SCIIRE). |
The table in the following example illustrates possible data extracted by SCIREF and SCIRTY.

|
SCIREF of CCH-1 [DBREF] |
SCIRTY of CCH-1 [WORD] |
|
|---|---|---|
|
1 |
CCH-2 |
ELEC |
|
2 |
CCH-11 |
ZIGB |
|
... |
||
|
10 |
Schematic instrument reference type is corresponding to schematic instrument reference where the same index.
CCH-1 has two SCIREF connections. It is connected with offline instrument (CCH-2) via electrical interface and it is connected with actuator via the ZigBee interface.