Specific Import Shape Information
- Last UpdatedFeb 27, 2024
- 3 minute read
The table below provides some specific information for each kind of shape to be imported:
|
Category |
Type |
Conn. Points |
Notes |
|
Equipment items |
Equipment |
Any number |
|
|
Sub-equipment |
Any number |
||
|
Nozzle |
2 |
The point to be used for connecting the nozzle to an equipment item should be of Outward type. The point where a pipe branch should be connected should be Inward. |
|
|
Electrical connection |
2 |
The point to be used for connecting the elconn to an equipment item should be of Outward type. The point where a cable should be connected should be Inward. |
|
|
Pipeline elements |
Pipeline, Branch, Tube |
N/A |
These must be connector type shapes. Linestyles can be assigned before importing. In case any indication of flow direction is to be used, Begin is considered to be Arrive, and End is considered to be Leave. To import the shape as a Pipeline, the line created should be horizontal or curved or L shape. |
|
Pipe components |
Valve |
For 2-way:2 For 3-way:3 For 4-way:4 |
Assign connection points so that the desired Arrive (= connection point 1) and Leave (= connection point 2) for the main flow will be achieved. |
|
Instrument |
2 |
||
|
Pipe Destination |
1 |
||
|
Pipe components - Fitting |
Cap Closure |
1 |
|
|
Blind flange Coupling Filter Flange Reducer Trap Vent Weld |
2 |
For a reducer, the first connection point (arrive) is normally on the large side. |
|
|
Other |
|||
|
Cross |
4 |
Assign connection points so that the desired Arrive - Leave (main flow) will be achieved. |
|
|
Olet Tee |
3 |
Assign connection points so that the desired Arrive - Leave (main flow) will be achieved. |
|
|
Instrumentation |
Instrumentation line, Instrumentation branch, Instrumentation tube |
N/A |
These must be connector type shapes. Linestyles can be assigned before importing. In case any indication of flow direction is to be used, Begin is considered to be Arrive, and End is considered to be Leave. |
|
Instrument relationship shape |
N/A |
This must be a connector shape. Linestyle can be assigned before importing. When connecting to instruments, Begin is considered to be 'from-reference', and End is considered to be 'to-reference'. |
|
|
Actuator |
2 |
The point to be used for connecting the actuator to component items should be of Outward type. The point where an instrumentation line (tube) or instrument relationship shape should be connected should be Inward. |
|
|
Offline Instrument |
Any number |
During Import Shape, an attachment control handle will automatically be added to the shape if it does not already exist in the shape sheet. |
|
|
HVACline elements |
HVACline, HVAC branch, Duct |
N/A |
These must be connector type shapes. Linestyles can be assigned before importing. In case any indication of flow direction is to be used, Begin is considered to be Arrive, and End is considered to be Leave. To import the shape as a HVAC line, the line created should be horizontal or curved or L shape. |
|
Inline HVAC Components - HVAC Fitting |
Air handling unit Cowl Grille Mesh Plate Taper |
1 |
|
|
Branch connector Damper Fan Flexible joint Offset Plenum Silencer |
2 |
||
|
Straight Transformation piece |
|||
|
Three way |
3 |
||
|
Cable elements |
Cable Multi-cable |
N/A |
Must be a Connector type shape. To import the shape as a Cable, the line created should be horizontal or curved or L shape. |
|
Annotation |
Label |
None |
|
|
Multilabel |
None |
||
|
Title block |
None |
||
|
Off-page connectors |
Off-page connector, incoming |
1 |
|
|
Off-page connector, outgoing |
1 |
||
|
Line splitter |
Line splitter |