Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Diagrams

AVEVA Diagrams 14​.3 Release Notes

  • Last UpdatedFeb 27, 2026
  • 5 minute read

AVEVA Diagrams 14.3, released on February 27, 2026, is a full-service feature that delivers multiple enhancements in licensing implementation, environment configuration, DEXPI export improvements, and overall product stability.

This application supports Windows 11 and Windows Server 2022.

For more information on product features and functions, refer to AVEVA Documentation Portal.

Expectations and limitations

The following expectations and limitations should be considered for this release:

  • DEXPI 4.0.1 class mapping limitations: Class mapping in this release is limited to the existing DB element types in the schematic database. Equipment and instrument classes from P&IDs cannot be mapped to corresponding DEXPI classifications. The next fix release will extend configuration options to map equipment and instrument classifications using user-defined component attributes.

  • Datasheets view: The Datasheets view has been removed from Diagrams in this release. To view datasheets in the same project context, use the feature available in AVEVA Engineering.

  • Custom installation path warning: A warning appears if Diagrams is installed in a directory other than the default path. This does not affect functionality and will be corrected in a future release.

  • Folder naming restrictions: Avoid using spaces in installation, project, defaults, and USER DATA folder names. Diagrams does not support folder paths containing spaces.

  • Compatibility with older products: If you are using AVEVA Diagrams 14.1 or later, you cannot use the versions of Diagrams included with AVEVA PDMS 12.1 SP4 or AVEVA Hull and Outfitting 12.1 SP4. These versions are not compatible.

  • Administration and Lexicon compatibility: Once you start using AVEVA Administration 1.5, you cannot use the Admin or Lexicon versions included with PDMS 12.1 SP4 or Hull & Outfitting 12.1 SP4.

  • Visio template settings: For drawing templates used in AVEVA Diagrams, disable the Auto Size option in the Visio Design tab, or disable Let Visio expand the page as needed option in Page Setup.

  • Office and Visio upgrade requirement: Before upgrading Microsoft Office and Visio, uninstall any existing Office 365 Apps or Microsoft Visio installations.

New features and enhancements

The following new features and enhancements were added:

  • Upgraded licensing implementation to meet AVEVA Unified Engineering requirements. Solution: Upgrade to AVEVA Diagrams 14.3.

  • Removed dependency on the system variable APPSTREAM_SESSION_CONTEXT.

  • Added administrator configurable environment variable: Aveva_connect_Authority_Url (https://signin.dev-connect-aveva.com).

    Incident/Case Number

    Defect Number

    Description

    Not applicable

    4507704

    Symbol shape catalog is now available when exporting drawings in DEXPI format using schema version 3.3.3.

    Not applicable

    4514905

    New prompt during DEXPI export notifies users when an output file already exists.

    Workflow:

    Export selected drawing to DEXPI format.

    A pop-up appears allowing the user to proceed or cancel.

    960622722

    4082124

    New feature: Delete multiple drawings from project database.

    Workflow:

    Open Schematic Model Manager, navigate to Tools menu, and then select Delete Multiple Drawings.

    Select one or multiple drawings and select Delete.

    960666406

    4216500

    Redefinition of DEXPI shape catalog export.

    Workflow:

    The application now analyzes the project shape catalog and exports one instance of each available symbol found in project stencils.

    Each exported symbol instance in the drawings now references the single unique symbol definition from the shape catalog.

Resolved issues

The following issues reported in earlier releases have been resolved in this version.

Incident/Case number

Defect number

Issue

Resolution

Not applicable

4220178

We improved the graphical representation accuracy of drawing entities exported using the DEXPI format.

Upgrade to AVEVA Diagrams 14.3, then export the drawings again.

960619068

960598834

3999745

Diagrams slowed down when users opened multiple drawings in a single session.

Because upgradingAVEVA Diagrams to a 64-bit architecture is not possible, we introduced a workaround in AVEVA Diagrams 14.3.

The application now monitors memory usage from the command line and displays messages that show both the memory currently in use and the remaining available memory.

Because upgrading AVEVA Diagrams to a 64-bit architecture is not possible, we introduced a workaround in AVEVA Diagrams 14.3. The application now monitors memory usage from the command line and displays messages that show both the memory currently in use and the remaining available memory.

Recommendation:

When the remaining memory becomes low, restart the application to prevent slow performance or unexpected behavior.

Known issues

The following known issues and deferred items have been identified for this release. Where available, recommended workarounds are provided:

Incident/Case number

Defect number

Issue

Recommended workaround

962672686

4419835

The Change Group option does not move instrument loop reference as expected.

Upgrade to Diagrams 14.3 and use the Change Group option.

962623036

4379051

Attribute and symbol mappings are not captured in the exported DEXPI file.

Upgrade to Diagrams 14.3, configure symbol and attribute mappings in the application, and re-export the drawings using schema version 4.0.1.

960542187

3742798

Replace symbol does not work for SCDUCT type elements.

Upgrade to Diagrams 14.3 and replace the SCDUCT type symbol on the target drawing.

960655701

4101825

A fatal error occurs when running consistency validation in batch mode.

Upgrade to Diagrams 14.3 and run the consistency check in batch mode again.

960652313

4100520

Schematic Model Manager does not import pipelines with the expected structure.

Upgrade to Diagrams 14.3 and import external drawings using the import drawing option in Schematic Model Manager.

960552693

4032266

Importing external drawings using Schematic Model Manager delivers inconsistent results when drawings are imported in different order.

Upgrade to Diagrams 14.3 and import external drawings using the import drawing option in Schematic Model Manager.

960608440

3959791

Drawings exported to DWG format in batch mode generate invalid DWG files.

Upgrade to Diagrams 14.3 and re-export the selected drawings in batch mode.

960598631

3952416

AVEVA Diagrams crashes repeatedly in the UEoC environment.

Upgrade to Diagrams 14.3.

Third-party products and components

The following are the third-party components without digital signatures (SHA-256 Hash Provided for Integrity verification):

File Name

SHA-256 Hash

AWSSDK.CloudWatchLogs.dll

E0B2D0CA8D81F019DDCAD0709987691523F026A6117CA4847824E2A4C7E77B95

AWSSDK.Core.dll

03971E2E6855E0E80925CADDEE42144F0B1B0E87C249B1A490CF9159A688D93A

AWSSDK.S3.dll

CA6E2AB81D9821F2AEC5C7E670B43D09D01FB4FA04A56301DDA6AACAF41AFA26

axinterop.acropdflib.dll

8CAA032C86E07F7AFCA0BCCF27CD508EB13DCE375721D6F107F6380FF85A7D4E

AxInterop.Microsoft.Office.Interop.VisOcx.dll

307E00488D122C54875EAB9BF2B1DFFDEE67C2BC597C1E3F12EAFDBDEAC6BECF

AxSHDocVw.dll

E1727C31751BCD63F7A80BA9AD587CC42B69DF2602355CEFB09B066E8927E7C0

dscrt40.dll

673959A91945B76CB8E267D25979EDA0AE93429739AFFBE740300515F435351B

fm40base.dll

AE2AC1B2A68D33BABFD7C2E040095C4E68F27130FE1D900685FD8901A962D3F4

fm40tiff.dll

88CD9995C66A5AB6C5E21E886E6B024898F39EEE78626AE5A02FD9BA81B70034

interop.acropdflib.dll

2543C6D7F7A986A99E5CB1055FC86D3146EFC97BF7FC3B51CDEE1F42A5DCF1A5

Interop.MSXML2.dll

3AC6BA26C825418CC0969DA38256FB010A189309996C73AF7E5FE90C35B84F88

Interop.SolutionUtils.dll

BCA18D666F7EB1677CCC4E936CD05DFE9AD90CBFBA495513F5817C8A0D43F91A

ixclib40.dll

2AE207DFDB2A08E9AD02793B2A381188E3ABCE4E43E5D60C4BADB96612288640

libprotobuf-lite.dll

F526DC0419A549E3352BFA9FFBABEFD4CA43037162E45A4A0B8785AB7FBDB86F

netlib40.dll

300ADF40F539FDBBDC4CE16C816CCEDB47FD390B00521467C84617823F6212AA

Northwoods.Go.dll

0DF46BC551C86292B0BD872A739AAA88631901B2FFC0298BF100278D16E4D448

Northwoods.Go.Draw.dll

2B74F784FD78B6A90265F11B6883D40D4799F2B9ED06E8C5973445D9571E2F2D

Northwoods.Go.Instruments.dll

2A0DEC142B065E30825B278BC71406D286DB1C95C9E4A103D33FB3DA338E7677

Northwoods.Go.Layout.dll

AEC51B56311C73C4F5899C871961B646BD1EEF4BC1AD27E0D143DBE69E0409B1

Northwoods.Go.Pdf.dll

A20D4CB649DC24BC7A935D7E759F58FB464261C97D6EADE6561FFAD4A73B3965

Northwoods.Go.Svg.dll

391A774DE887B66BBA3C5DF760D0E52865F451F53D25FC6427DB01C368ED0AB7

Northwoods.Go.Xml.dll

1CC68CF318E2CE79676A6A8BDE860F5AE3A41B2C833D854773C065C1AF0E450F

Northwoods.GoWPF.dll

8E4C2B5BCF70FE263E427E875E2C682B3EDC717416E968C7542E7A63FE588612

pxclib40.dll

5A81FDA71B1ABB21D88EE5257EB613C72DC6044F4509710AAB4EA17C2120BF09

xccdx40.dll

B2C4E9B91AA24EAB4991D9D96EB9568A4DBEB1849406B46C28EB2289EBC427EF

Security information and guidance

The following are the security issues addressed:

  • Project login security: Generic usernames previously shown during project login have been removed. Users must enter the required username and password to access the application.

  • Use of unsecured URL in DEXPI 4.0.1 export: The ISO Export workflow for DEXPI 4.0.1 uses the URL: http://data.posccaesar.org/rdl/ in Symbol Mapping to look up Component Class values and Component URIs. A link labeled Search for Component Class and URI opens this URL in a browser to search the reference data library.

    Warning: This URL does not support HTTPS. Although the data is not sensitive, accessing the site may introduce security risks.

  • Design Reuse licensing: The Design Reuse feature, shared by AVEVA Engineering and AVEVA Diagrams, requires a separate license. LAAS customers must obtain the license V00FN548 – AVEVA Design Reuse to enable this functionality.

  • AIM Framework and DirectX prerequisites: If the required versions of the AIM Framework runtime or DirectX are missing, the AVEVA Diagrams 14.3 installer installs them automatically.

  • AIM Framework 4.8 support: AIM Framework 4.8 installs only on Windows 11 version 22H2 or later. It is preinstalled on supported versions.

  • Windows version check: To check the Windows 11 version, run winver from the Start menu.

  • Display scale recommendation: During Windows 11 installation, the system sets a default display scale. AVEVA recommends keeping the scale at 100%. To change it, open Display Settings, update the value, and select Keep Changes.

In This Topic
Related Links
TitleResults for “How to create a CRG?”Also Available in