Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Diagrams

Supplied Rules

  • Last UpdatedMar 28, 2024
  • 1 minute read

The following rules are supplied with the product:

  • Unset HREF/TREF Components: If a branch is unconnected and ends on a component, then the DESC attribute is output as the LLFROM or LLTO attribute (see example above).

  • Unset HREF/TREF SCTUBING: If a branch ends with an SCTUB, then the text 'Open Pipe' is output for the LLFROM or LLTO attribute.

  • HREF/TREF Components: If a branch terminates at a component of another SCPLINE or PIPE, then the name of the SCPLINE or PIPE is provided as the LLFROM or LLTO attribute value.

  • SCNOZZLEs: the name of the owning equipment is output with the nozzle name in brackets.

  • Equipment: the name of the Equipment is output with its DESC attribute in brackets.

  • Offline Instruments: The name of the instrument is output with the DESC attribute in brackets.