Integration UDA Definition
- Last UpdatedAug 29, 2022
- 1 minute read
The UDAs must be defined in LEXICON if the matching process is to use them for storing source Database (DB) references. For further information, refer to Instrumentation, Electrical and P&ID Elements Matching.
The UDAs may be created in any UGROUP in a current dictionary DB. If used in conjunction with the specific module, it is suggested to include these UDAs in the same group.
The Integration UDAs should be created as Indexed UDAs with the following details:
|
UDA Name(s) |
UDA Type |
UDA Length |
Element Types |
|---|---|---|---|
|
pmg-sch-ai |
text |
50 |
SCINSTRUMENT SCOINSTRUMENT SCLOOP SCVALV SCACTUATOR |
|
pmg-sch-ae |
text |
50 |
SCEQUIPMENT |
|
pmg-engi-ai pmg-engi-ae pmg-engi-pid |
text text text |
50 50 150 |
Tags Instrumentation UDET(s) Tags Electrical UDET(s) Tags P&ID UDET(s) |
|
pmg-design-ai |
text |
50 |
CABLE EQUIPMENT INSTRUMENT SUBEQUIPMENT |
|
pmg-design-ae |
text |
50 |
CABLE EQUIPMENT |
|
pmg-cata-ai pmg-cata-ae |
text |
50 |
TABITEM GPART CABDATA SCOMPONENT CCORSET CABCORE TABQUESTION |
|
pmg-engi-edb pmg-sche-edb pmg-desi-edb |
text |
To suit relational source ID length |
Engineering DB Type(s) Schematic DB Type(s) Design DB Type(s) |
Note:
In order to store the source DB references for elements already imported, re-run Compare/Update
on the existing data, accept all rows even though there are no changes listed, and
complete the Update Database process.