Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Diagrams

Consistency Check Result

  • Last UpdatedNov 28, 2022
  • 1 minute read

The columns are as follows:

Column

Explanation

Shape

  1. The icon indicates the severity of the problem (Error, Warning or Information).

  2. Name of the Visio shape that the problem is related to.

Connection

Connection number of the shape which the problem is related to. This is only shown in case the problem is related to a certain connection point on the shape.

DB Element

Name of DB element that the shape is related to. This is only shown in case the problem is related to a shape that has a corresponding DB element.

Page

Page number in the drawing on which the related shape exists. This is only shown in case the message is related to a shape.

Problem

Problem text. See below for the list of problems that can be detected by the Consistency Check function.

Corrective action

In case any corrective action has been taken, this will be indicated in this column.

By clicking on each line in the dialog, the corresponding shape will be highlighted in the drawing. In case the shape is not visible in the current view, the system will pan and if necessary zoom out to make the entire shape visible.

The system will also attempt to bring back the drawing to a consistent state against the database in case any inconsistencies have been detected. This normally means that shapes will be disconnected or undefined in the drawing. No automatic updates will be done to the database.

Related Links
TitleResults for “How to create a CRG?”Also Available in