Application Server resolved issues - SP 2023 R2 P01
- Last UpdatedJul 17, 2025
- 4 minute read
This table describes important resolved issues in AVEVA Application Server 2023 R2 P01. Some issues that have been fixed in this release may not be listed.
|
Original Issue |
Related Issues |
Case/SR Number |
Description |
|
IMS 2985894 |
960354373 |
When using the warm redundancy option, the aaCALWrap.exe process consumed a great deal of memory. |
|
|
IMS 3018396 |
960341870 |
In some cases, after failover from the primary server to the backup server, some shelved alarms did not show in the shelved alarm list. The status of these alarms was still "shelved," they just did not appear when listing shelved alarms. |
|
|
IMS 3023716 |
960375402 |
In a Multi-Galaxy configuration, the warning message was logged continuously on the GR node. This happened because the passphrase solution could not be found. |
|
|
IMS 3039913 |
960380498 |
When System Platform was installed in a non-default location, such as on the D: drive, deploying WinPlatforms caused errors and warnings in the log and the platforms were not available in the OCMC Platform Manager. |
|
|
IMS 3040483 |
960381315 |
Importing objects via a package (.aaPKG) file incremented the objects' versions by two steps. |
|
|
IMS 3046335 |
960376548 |
Alarms which did not return to normal for a very long time (approximately one month) appeared in Historian with a negative duration. |
|
|
IMS 3067809 |
960390378 |
Improved performance when deleting objects. |
|
|
IMS 3081734 |
960352243 |
Objects that were set to Scan on Demand were not always added to the list for OI Server. As a result, these items were sometimes not scanned. |
|
|
IMS 3109688 |
960387634 |
GRAccess could not write to any attribute that had a description field. Therefore, it could not create any object that contained any attribute with a description field. |
|
|
IMS 3166242 |
960392759 |
In a warm redundancy configuration, after failover occurred, the EngineObjects[] attribute no longer contained a list of deployed objects. |
|
|
IMS 3198388 |
960395617 |
When deploying an OMI ViewApp that included object wizards, the PCS Framework used more than 90% of the server's CPU. |
|
|
IMS 3201271 |
960390809 |
If a galaxy was backed up using the Operations Control Management Console (OCMC), then a new galaxy was created from the backup, you could no longer connect to the original galaxy. |
|
|
IMS 3242289 |
960400382 |
Collecting diagnostic information using the default configuration could create an unlimited number of files in the ArchestrA temp folder. |
|
|
IMS 3259264 |
960403401 |
If an exported CSV file contains two objects which have attributes with the same name but different types (for example, one is Boolean and the other is a string), trying to import the CSV file fails with an error message. |
|
|
IMS 3260947 |
960396305 |
Low priority alarms were being historized even though the galaxy was configured not to do so. |
|
|
IMS 3261424 |
960404170 |
If you created an instance from a master template, then changed the default settings for an object wizard in the master template, you could not edit the instance or export it to a CSV file. |
|
|
IMS 3264570 |
960404338 |
If the input source and output destination for an attribute associated with an object wizard were different, the output destination was set to --- if a change was made to the object template. This occurred even if the attribute was created in the object instance and did not exist in the template. |
|
|
IMS 3270224 |
960405891 |
Importing a package file containing a graphic with multiple client controls which used the same dependent DLLs failed. |
|
|
IMS 3270262 |
960405918 |
With multiple people using the IDE at the same time, the aaGR service crashed every 15 to 25 minutes. |
|
|
IMS 3270629 |
3065034 |
960390172 |
Enabling the System Management Server slows down log in to OMI ViewApps at runtime. |
|
IMS 3278545 |
960407805 |
Longer than expected time to failover from one server to another caused unacceptably long gaps in historized data. |
|
|
IMS 3279907 |
960407298 |
There was a small memory leak in the module aaGlobalDataCacheMonitorSrv. Eventually, this caused the following warning to be written to the log repeatedly: . As the memory leak was very small, it could take several months before this warning appeared. |
|
|
IMS 3281737 |
960406315 |
Post-upgrade from System Platform 2023 P02 to System Platform 2023 R2, AVEVA.IOMBLS.ServiceHost.exe caused memory leak and then stopped responding. |
|
|
IMS 3282637 |
960407900 |
When using the Assign to option to assign an object to an area, typing in the list box the on the dialog did not move the list to match your entry. |
|
|
IMS 3293455 |
None |
Validating a large object sometimes caused a System.OutOfMemoryException and could cause the IDE to crash. For example, this could happen when migrating a galaxy that contained large objects. |
|
|
IMS 3303557 |
960411247 |
The I/O Mapping view showed attributes for an instance even if those attributes were excluded by object wizard choices. |
|
|
IMS 3318750 |
960391528 |
Closing and reopening the IDE caused deployed VIewApps to incorrectly show that they needed to be redeployed, even though they had not changed. |
|
|
IMS 3324307 |
960417221 |
Checking in changes to a template and propagating the changes to its children could take hours and then fail, even though the IDE showed that it had completed successfully. When this occurred, the template remained checked out and error messages were written to the logger, starting with something like: Error WWCdi Error 80040E14: Description 'Violation of PRIMARY KEY constraint 'PK__#trimatt__38174EC39114E2BF'. Cannot insert duplicate key in object 'dbo.#trimattr'. The duplicate key value is (512616, 1041602300). Line:308, Store proc:internal_ow_streamline_dynamic_a appeared |