Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

Application Server

Import protected objects

  • Last UpdatedJul 29, 2024
  • 2 minute read

The import objects procedure is the same for all objects, protected or unprotected. The following describes import preferences and results specific to importing protected objects:

Import Preferences

Result for Protected Objects

Objects with same Tagname and Codebase as an existing object:

  • Skip: Do not import

  • Overwrite objects if the imported configuration version is higher (default)

  • Overwrite objects regardless of configuration version

Overwrite preferences are governed by the Template Protection Change Management option, "Never overwrite an unprotected object with a protected object" (default).

  • Overwrites can occur if both the packaged and galaxy objects have the same protection status.

  • A protected object can overwrite an unprotected object only if specifically permitted by clearing the "Never overwrite ..." option.

  • When overwriting a protected parent object, protection is not cascaded to child objects. Unprotected child objects remain unprotected.

Base Templates with newer or older Codebases (or minor version updates):

  • Skip: Do not migrate

  • Migrate

Import and migration of base templates is unchanged by protected object import functionality.

Objects with same Tagname but with a different Codebase:

  • Skip: Do not import

  • Rename object in Galaxy

  • Rename importing object

Object renaming on import can occur only if the object to be renamed is not protected.

  • If the object in the Galaxy is protected, and the importing object is not, and Rename importing object is selected, the importing object is renamed to have the suffix "_new".

  • If the object in the Galaxy is unprotected, and the importing object is protected, and Rename object in Galaxy is selected, and the Never overwrite an unprotected object with a protected object option is not selected, the object in the Galaxy is renamed with the suffix "_old".

Related Links