You use the Device Data Transfer Console window in PI Manual Logger PC to transfer data manually between the PI Manual Logger PC database and mobile databases.

Users should wait until ActiveSync or Windows Mobile Device Center has recognized that a device is connected and cradled before they open the Device Data Transfer Console window. Otherwise, PI Manual Logger may prompt them for a location if the first entry in the Mobile Database Location Setup window is Load from mobile device.

Device Data Transfer Console

After a data transfer is complete, a tour run can remain on the device under the following conditions:

  • If the Import only completed tour runs option is selected on the Receive Options tab in the Device Data Transfer Options window, and a tour run has a status of In Progress.

  • If the Number of tour runs per tour to retain on the device after transfer value on the Send Options tab in the Device Data Transfer Options window is greater than zero.

PC Tour List

The PC Tour List pane lists the tours currently available in the PI Manual Logger database. The following tools are available.

Tool

Description

Refresh

Refreshes the list.

Logs

Opens data transfer logs from the current transfer session.

Note: When you close the Logs window, the transfer logs are not saved. Auditing information, however, such as send to PI events, exceptions, and tour changes, is logged by the tour run audit trail or the message log system and saved in the PI Manual Logger database.

Filter by

Enables you to enter a case-sensitive string to filter the tour list. You can include a * wildcard, for example Pump* displays only tours where the name begins with Pump.

Apply

Applies the filter to the tour list.

PC Tour Run List

The PC Tour Run List pane displays the status of all the tour runs currently available in the PI Manual Logger database.

Device Tour List

The Device Tour List pane lists tours on the currently connected mobile device. The following tools are available.

Tool

Description

Refresh

Refreshes the list on the device.

Transfer

Initiates a data transfer.

Info

Enables you to view information about the device.

Settings

Opens the Mobile Device Settings window.

Database

Enables you to select the local database file to be used for data transfer.

Device Tour Run List

The Device Tour Run List pane displays the status of tour runs on the currently connected mobile device.