Install PI Manual Logger MobilePC (disconnected mode)
- Last UpdatedNov 21, 2022
- 1 minute read
- PI System
- PI Manual Logger 2017 R2
- Visualization
Follow these instructions to install MobilePC with the same database schema as the Central SQL Server database.
-
A full implementation of Manual Logger PC must already be installed and configured.
-
The Central SQL Server database must already be installed and configured, as described in Installation of PI Manual Logger PC Client.
-
Install SQL Server Express and SQL Server Management Studio Express on the mobile PC.
-
Run the PI Manual Logger PC Client installation on the laptop.
-
Follow the same prerequisites as described in Prerequisites for PI Manual Logger PC Client installation.
-
You need only install Database Files and Client Application.
-
-
Copy the PIMLWindowsMobilePC SQL Server database template files (PIMLWindowsMobilePC.mdf and PIMLWindowsMobilePC_Log.ldf) located in the PIPC\PIMLWindows\Data folder to another folder on the mobile PC, for example a folder named C:\PIMLData. The files must be writable and the folder must be accessible by the SQL Server account, as described in SQL Server configuration.
Note: The same template file can be used for SQL 2016 Express, 2014 Express, 2012 Express, SQL 2008 Express or SQL 2005 Express.
-
Open the SQL Server Management Studio Express and attach the database, as described in Attach template files for SQL Server.
-
Configure the users, as described in Add a user account to PIMLWindows database.
-