Configure Credential Manager if installing on an application server that isn't in a domain
- Last UpdatedApr 07, 2025
- 1 minute read
Configure Credential Manager if installing on an application server that isn't in a domain
Note: This section only applies if installing PI Vision on an application server that isn't in a domain.
Configure Credential Manager to allow connections to the AVEVA Identity Manager server for identity client registration.
-
On the PI Vision server, open the Credential Manager application.
-
In Credential Manager, select Windows Credentials, then select Add a Windows credential.
-
For the Internet or network address, enter the name of the AVEVA Identity Manager server.
-
Enter the username and password of a user that has administrative rights on the AVEVA Identity Manager server.
-
Select OK to save the new Windows credential.