Configure data entry options

  • Last UpdatedNov 09, 2026
  • 5 minute read

Use the Configure Data Entry pane to set options for the symbol.

  1. Right-click the symbol and select Configure Data Entry to open the Configure Data Entry pane.

  2. Under Columns, select a column to access the check boxes that control that column.

    Select Show Column to include the column or clear it to exclude the column. The Show Column check box is selected for columns shown in bold.

    Note: If you want users to be able to enter custom timestamps for each data value that they enter in the symbol, you should show the New Time column. For example, if you want users to be able to replace existing data values to fix incorrect data, users need to enter timestamps that exactly match existing timestamps. If the column is not shown, all values are written with the Default Timestamp setting. You might not want to show the New Time column if you set the Default Timestamp to now and you want timestamps to always reflect the time of entry (now).

    You can select one or more columns in the list then choose an Alignment option to set if text is aligned left, center, or right within the column cells.

    You can select Wrap Text to display text in the column on multiple lines or you can clear it to keep the text on one line. When Wrap Text is not selected, values in the column are truncated if they do not fit within the column's width.

  3. Under Write Options, set the options described below.

    In the Default Timestamp field, enter the time that you want to be associated with each value that is entered in the symbol by default. If you want timestamps to reflect the current time when the entry occurs, enter an asterisk (*). For more information about the formatting and syntax that you can use in this field, see Use PI time.

    Note: When entering values in the symbol, users can override the Default Timestamp with a custom timestamp if you show the New Time column.

    In the Update Mode field, select how you want PI Vision to determine whether entered data creates a new data entry or if it replaces the value for an existing data entry. The options are described below.

    Update Mode option

    Description

    Replace

    Users can add new values and replace existing values.

    A new value is added: When the value that is entered in the symbol has a timestamp that does not match the timestamp of any existing value.

    An existing value is replaced: When the value that is entered in the symbol has a timestamp that matches the timestamp of an existing value.

    Insert

    Users can only add new values; they cannot replace existing values.

    A new value is added: When the value that is entered in the symbol has a timestamp that does not match the timestamp of any existing value.

    —OR—

    When the value that is entered in the symbol has a timestamp that matches the timestamp of an existing value. In this scenario, the new value is saved as an additional data point and the existing value with a matching timestamp is not changed. As a result, there is more than one data point with the same timestamp.

    No Replace

    Users can only add new values; they cannot replace existing values.

    Note: This is an advanced option that is not recommended for most users.

    For more information about this option, see AFUpdateOption_Enumeration.

    Replace Only

    Users can only replace existing values; they cannot add new values.

    Note: This is an advanced option that is not recommended for most users.

    For more information about this option, see AFUpdateOption_Enumeration.

    Insert No Compression

    This option works the same as the Insert option described above, except compression is not applied to the values that are entered in the symbol.

    Note: This is an advanced option that is not recommended for most users.

    For more information about this option, see AFUpdateOption Enumeration.

  4. Under Rows, set the options described below.

    Note: You cannot add rows to the table from the Configure Data Entry pane. Rows are added to the symbol only when you add data items to the symbol from the Assets pane.

  5. In the Default Label field, select what you want to appear in the table for the rows' label names, by default. The options are:

    Default - PI Vision's default way of displaying row labels is used. When this option is selected, in many cases the row name is displayed as Asset | Attribute. However, this varies for certain data types.

    Asset - The row label is the row data's asset name that is configured in PI AF.

    Attribute - The row label is the row data's attribute name that is configured in PI AF.

    Description - The row label is the row data's description text that is configured in PI AF.

    Note: You can customize the label for each individual row to something different than the Default Label selection by using the Label field further below.

    Use the rows list to select, move, or delete a row:

    • Use the left pair of up or down arrows to move the selected row higher or lower on the table.

    • Use the right pair of up or down arrows to move the selected row all the way to the top or bottom of the table.

    • Select X to delete the selected row.

      To change the name that appears in the table for any individual row, select the row in the list, then in the Label field select an option. If you select Use table default, the option selected in the Default Label field is used for the row name. Otherwise, you can select a pre-determined name that comes from PI AF or you can use custom text by selecting <Custom> then replace <Custom> with the text that you want to appear as the row name.

      Under Value Limits, the Min and Max fields allow you to set minimum and maximum limits for the values that users are allowed to enter for the selected row. If a user attempts to enter a value that falls outside of this range, it is automatically rejected. The Value Limits fields are available only for data items with numeric data.

  6. Under Style, select the table style that best accommodates your work environment.

    Choose from Dark, Light, or Striped.