Configure value entry options
- Last UpdatedNov 09, 2026
- 2 minute read
Use the Configure Value Entry pane to set options for the symbol.
-
Right-click the symbol and select Configure Value Entry to open the Configure Value Entry pane.
-
In the Timestamp field, enter the time that you want to be associated with each value that is entered in the symbol. If you want timestamps to reflect the current time when the entry occurs, enter an asterisk (*). For more information about the formatting and syntax that you can use in this field, see Use PI time.
-
In the Update Mode field, select how you want PI Vision to determine whether entered data creates a new data entry or if it replaces the value for an existing data entry. The options are described below.
Update Mode option
Description
Replace
Users can add new values and replace existing values.
A new value is added: When the value that is entered in the symbol has a timestamp that does not match the timestamp of any existing value.
An existing value is replaced: When the value that is entered in the symbol has a timestamp that matches the timestamp of an existing value.
Insert
Users can only add new values; they cannot replace existing values.
A new value is added: When the value that is entered in the symbol has a timestamp that does not match the timestamp of any existing value.
—OR—
When the value that is entered in the symbol has a timestamp that matches the timestamp of an existing value. In this scenario, the new value is saved as an additional data point and the existing value with a matching timestamp is not changed. As a result, there is more than one data point with the same timestamp.
No Replace
Users can only add new values; they cannot replace existing values.
Note: This is an advanced option that is not recommended for most users.
For more information about this option, see AFUpdateOption_Enumeration.
Replace Only
Users can only replace existing values; they cannot add new values.
Note: This is an advanced option that is not recommended for most users.
For more information about this option, see AFUpdateOption_Enumeration.
Insert No Compression
This option works the same as the Insert option described above, except compression is not applied to the values that are entered in the symbol.
Note: This is an advanced option that is not recommended for most users.
For more information about this option, see AFUpdateOption Enumeration.
-
Under Value Limits, the Min and Max fields allow you to set minimum and maximum limits for the values that users are allowed to enter in the symbol. If a user attempts to enter a value that falls outside of this range, it is automatically rejected. The Value Limits fields are available only if the symbol's data item has numeric data.