Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ PI Vision™

2026 Release Notes

  • Last UpdatedNov 17, 2026
  • 9 minute read

Overview

AVEVA PI Vision 2026 (version 3.12.0) is a web server-based product that allows you to visualize, assess, and monitor PI System data using any modern web browser.

Expectations and limitations

Software requirements

For PI Vision 2026, there are new minimum software requirements:

Increased storage recommendation

As a result of the new audit log feature and the ability to save displays’ previous revisions, the minimum storage recommendation for a PI Vision database increased to 250 MB of storage plus 10 MB per user (previously it was 200 MB of storage plus 5 MB per user). A display’s revisions are compressed in the database so that they consume significantly less space than an active display; the new recommendation accounts for compression.

Display Utility requires a trusted certificate

To improve security, a PI Vision server must now have a trusted TLS certificate for the Display Utility to connect to it. If your PI Vision server does not have a trusted certificate and your security policy allows it, you can change your configuration settings to bypass the requirement.

Changes to CSP headers

To improve security, additional directives were added to PI Vision's Content Security Policy (CSP) headers. These measures help ensure that PI Vision loads content only from trusted sources. After upgrading to PI Vision 2026, custom symbols that depend on external sources may not load properly. To allow these sources, customize your CSP headers by adding them to the CspCustomPolicy setting. For more details, see the PI Vision Extensibility Guide. If you are already using customized CSP headers, those customizations are retained through the version upgrade.

New features and enhancements

Major features

  • Data entry symbols

    There are two new symbols that allow users to manually write data values to PI Points and PI AF attributes. The data entry symbol lets you enter values for multiple PI Points or PI AF attributes, while the value entry symbol is a simpler, smaller input box, ideal for crowded displays, that lets you enter values for a single PI point or PI AF attribute. When using these symbols, each data value manually entered is saved with a timestamp that can reflect either the date and time of entry (now) or a different specified time. You can configure the symbols to let users add new data values, replace existing values, or both.

    On the Administration site, administrators can restrict data entry by disabling the feature entirely or by allowing it only for selected identities.

  • Data status flags

    In the user settings, each user can now choose to have icons appear on displays when data is flagged as questionable, substituted, or annotated. Showing data status icons helps to quickly alert you whenever data has a flag, which can mean that the data is inaccurate. If data has an annotation, you can view the annotation text.

  • Cursor statistics

    A new cursor statistics feature can be enabled in the Ad Hoc Workspace and in pop-up trends. Cursor statistics provide summarized statistical information about the data that occurred over a selected period of time, and they also let you check how much time elapsed between two selected points on the trend.

  • Revision history

    For each display, PI Vision now saves a revision history so that you can view and restore previously saved revisions. For example, if unwanted changes are made to a display, the revision history lets you roll it back to a previous revision. An administrator can configure how many past revisions PI Vision saves for each display.

  • Audit log

    A new audit log provides a history of change events for your displays and folders, logging each instance when any display or folder is created, modified, or deleted. The log provides the date and time when each change occurred, the user who made the change, and the ID of the affected display or folder.

Symbol and display enhancements

  • Trend cursors controlled by keyboard

    To move trend cursors left and right to different timestamps, you can now use the left and right arrow keys on your keyboard. You can move the trend cursors in greater increments by holding down the Ctrl key before selecting the arrow keys. In previous versions, you could move trend cursors only by dragging them.

  • More filters for search criteria

    When setting up either dynamic search criteria for a symbol or search criteria for a collection, you can now use up to 25 filters to search based on asset attribute values. In previous versions, the limit was 5 filters.

  • Calculation units label

    For calculations that are based on PI points from a Data Archive, you can now enter a units label that appears with the calculation value on displays. This is a simple text label and it does not allow you to convert the calculation value to a different unit of measure.

  • XY plot improvements

    The XY plot symbol was revised to provide significant improvements in performance. For example, the symbol loads much faster when you resize, zoom, or pan. Also, the default maximum number of data points that can be plotted for each pairing of XY data increased from 10,000 to 25,000.

New user setting

  • Option for how links open

    In the user settings, each user can now choose to have links open in either the current browser tab or in a new tab by default. This setting applies only to links that automatically appear on displays, such as clickable events in events tables and whenever attributes have values that are links.

    Note: This setting does not apply to navigation links that you create manually. Each navigation link has its own setting that controls how the link opens for all users.

Administration enhancements

  • View Display Permissions by Identity report

    A new View Display Permissions by Identity report is available on the Administration website, allowing you to review which identities have access to any given display. You can also filter the report by a single identity to quickly check which displays a particular identity has access to.

  • Defaults for user settings

    On the Administration website, administrators can now set default options for the user settings that affect the appearance and functionality of displays. Each user in PI Vision can individually override these defaults through their user settings.

  • Display Utility improvements

    The Display Utility was improved to make it easier to change the permissions that are applied to displays. Additionally, the utility now shows the permissions that are currently applied to each display more clearly.

Resolved issues

The following items were resolved:

Article Number

Description

106028

Value symbol moves when alignment is set and enclosing group is copy/pasted

092855

XY Plot traces with 'Connecting Line' enabled are always displayed in front of traces with markers only

103573

PI Vision shows digital states values from new Digital Set for old PI Points events that were referencing an older Digital Set at the time

105763

Thumbnail is displayed incorrectly when group symbol has stale configuration properties

105861

PI Vision time series table shows unexpected events at or outside its time range for formula and table lookup data reference attributes

105860

Time series table shows the same timestamp for all events for a table lookup data reference attribute with a static attribute filter

105899

Timebar Revert button does not affect Events Tables when time range set to Timebar Duration

105901

Folders can't be selected for offline display files or when filtering and moving displays in PI Vision Display Utility

109886

Open Link context menu doesn't show up on columns where it should and shows up where it shouldn't

108123

Trend legend shows "No Data" after applying time range of an event frame with subseconds in its end time

109141

Transposing a table with a sorted attribute column results in the entire table disappearing

109416

PI Vision Trend Stalls (Spinning Wheel) When Adding Tag with 16-Digit Values

109613

Custom Symbol Configuration doesn't show in the Right-Click Context Menu after Upgrading to PI Vision 2025

109799

Event frame links do not offer open in new/same tab context menu option

110165

PI Vision Events Search pane shows ? in drop-down list for Custom Time Range time selector

112332

PI Vision returns “Use of key 'Failover Partner' requires the key 'Initial Catalog' to be present.” incorrectly, since there is no Failover Partner

110722

PI Vision 2024/2025 Text symbol behavior

110857

PI Vision images fail to load after app pool recycle when using OIDC

092852

Ideographic Space in the Text Symbol Displays Differently in PI Vision 2024

112529

Display Utility does not load PI Vision displays from nested folders

111352

PI Vision table properties such as multistate displayed on wrong row when sorting by column header

111860

PI Vision scale label color inside trend doesn't follow Foreground color

112479

PI Vision Display Utility does not support Inherit Permissions

112297

Current Identity AF Server (DisplayGroupsServer) not shown on Admin site if it's not in the KST

114236

PI Vision shows no visual indicator when Event Frame search results are truncated

112594

Popup Trend Ignores Display Background Color in PI Vision 2025

112921

PI Vision missing some Data Item Details for custom point class type

113846

PI Vision PIWebApiGateway corrupts the binary file streams passed through PI Web API /mediadata endpoint

113864

Fit-all zoom settings are very inconsistent

114036

Override permissions on home folder causes 500 Server Error

114251

PI Vision trend shows inconsistency when using different scale configurations for digital tags

118753

Scale Groups dialog box not usable (incorrect rendering) when PI Point / AF Attribute name is long.

116123

Transposed ACT symbol allows you to set a custom label for the attributes but after saving it it disappears

117315

Ad Hoc Workspace summary table is missing the "Delete Trace" option.

117868

PI Vision cannot sort collections on child attribute template value

121777

PI Vision uses outdated Time Zone mappings

Known issues

Known issues can be reviewed in the Customer Portal. For instructions on how to display a list of known issues, refer to How do I see Release Announcements, Alerts, Known Issues, and Knowledge Articles relating to my products? To review open enhancement requests, refer to the Feedback Portal.

Security information and guidance

We are committed to releasing secure products. This section is intended to provide relevant security-related information to guide your installation or upgrade decision.

We proactively disclose aggregate information about the number and severity of security vulnerabilities addressed in each release.

No new security vulnerabilities were identified or fixed in AVEVA PI Vision 2026.

Known vulnerabilities and their mitigations for this release are listed in the following table:

Component

Version

CVE or Reference

CVSS

Mitigation

jQuery Mobile

1.3.2

CVE not available

Reference:

https://gist.github.com/jupenur/e5d0c6f9b58aa81860bf74e010cf1685

8.4

Vulnerable code is not present.

libexpat

2.8.1

CVE-2026-50219

7.1

Vulnerable code is not present.

libexpat

2.8.1

CVE-2026-56131

7.1

Vulnerable code is not present.

libexpat

2.8.1

CVE-2026-56132

7.1

Vulnerable code is not present.

libexpat

2.8.1

CVE-2026-56403

7.1

Vulnerable code is not present.

libexpat

2.8.1

CVE-2026-56404

7.1

Vulnerable code is not present.

libexpat

2.8.1

CVE-2026-56405

7.1

Vulnerable code is not present.

libexpat

2.8.1

CVE-2026-56406

7.1

Vulnerable code is not present.

libexpat

2.8.1

CVE-2026-56407

7.1

Vulnerable code is not present.

libexpat

2.8.1

CVE-2026-56408

7.1

Vulnerable code is not present.

libexpat

2.8.1

CVE-2026-56410

7.1

Vulnerable code is not present.

libexpat

2.8.1

CVE-2026-56411

7.1

Vulnerable code is not present.

libexpat

2.8.1

CVE-2026-56412

7.1

Vulnerable code is not present.

libexpat

2.8.1

CVE-2026-72522

7.1

Vulnerable code is not in execution path.

libexpat

2.8.1

CVE-2026-77214

7.1

Vulnerable code is not present.

libexpat

2.8.1

CVE-2026-102633

7.1

Vulnerable code is not present.

libexpat

2.8.1

CVE-2026-115506

7.1

Vulnerable code is not present.

libexpat

2.8.1

CVE-2026-56409

6.5

Vulnerable code is not present.

libexpat

2.8.1

CVE-2026-66046

6.5

Vulnerable code is not present.

libexpat

2.8.1

CVE-2026-93990

6.5

Vulnerable code is not in execution path.

libexpat

2.8.1

CVE-2026-76957

6.4

Vulnerable code is not present.

libexpat

2.8.1

CVE-2026-113351

5.2

Vulnerable code is not present.

libexpat

2.8.1

CVE-2026-117610

5.2

Vulnerable code is not present.

libexpat

2.8.1

CVE-2026-118370

5.2

Vulnerable code is not present.

libexpat

2.81.1

CVE-2026-124317

4.2

Vulnerable code is not present.

libexpat

2.8.1

CVE-2025-66382

3.3

Vulnerable code is not present.

libjpeg-turbo

3.1.4

CVE-2026-75466

5.9

Vulnerable code is not present.

libpng

1.6.58

CVE-2026-3713

6.6

Vulnerable code is not present.

libpng

1.6.58

CVE not available

Reference: https://github.com/pnggroup/libpng/security/advisories/GHSA-qvg3-h654-xq3j

5.2

Vulnerable code is not in execution path.

Telerik Kendo UI Core

2023.3.1010

CVE-2026-108116

7.5

Vulnerable code is not present.

Telerik Kendo UI Core

2023.3.1010

CVE-2026-106163

6.5

Vulnerable code is not present.

Telerik Kendo UI Core

2023.3.1010

CVE-2026-106147

5.4

Vulnerable code is not present.

Telerik Kendo UI Core

2023.3.1010

CVE-2026-106148

5.4

Vulnerable code cannot be controlled by adversary.

Telerik Kendo UI Core

2023.3.1010

CVE-2026-106149

5.4

Vulnerable code cannot be controlled by adversary.

Telerik Kendo UI Core

2023.3.1010

CVE-2026-106151

5.4

Vulnerable code is not present.

Telerik Kendo UI Core

2023.3.1010

CVE-2026-106153

5.4

Vulnerable code cannot be controlled by adversary.

Telerik Kendo UI Core

2023.3.1010

CVE-2026-106160

5.4

Vulnerable code cannot be controlled by adversary.

Telerik Kendo UI Core

2023.3.1010

CVE-2026-106161

5.4

Vulnerable code is not in execution path.

Telerik Kendo UI Core

2023.3.1010

CVE-2026-106157

4.7

Vulnerable code cannot be controlled by adversary.

Telerik Kendo UI Core

2023.3.1010

CVE-2026-106158

4.7

Vulnerable code is not present.

Telerik Kendo UI Core

2023.3.1010

CVE-2026-106159

4.7

Vulnerable code is not present.

Telerik Kendo UI Core

2023.3.1010

CVE-2026-106162

4.7

Vulnerable code is not present.

zlib

1.3.2

CVE-2026-85091

7.3

Vulnerable code is not present.

Distribution kits

The distribution kit file for this AVEVA PI Vision release is AVEVA PI Vision_2026_.exe.

Note: The MUI Language Pack is included in the distribution kit.

In This Topic
Related Links